Fulltext results:
- Prospects for the modernisation of existing buildings using highly efficient components
- nt with Passive House components, Protocol Volume No. 23 of the Research Group for Cost-effective Pass... n of harmful substances in rooms, Protocol Volume No. 23 of the Research Group for Cost-effective Pass... reis kostengünstige Passivhäuser, Protocol Volume No. 17, 1. Auflage, Darmstadt, 1999. Feist, W.: Requ... or Cost-effective Passive Houses, Protocol Volume No. 17, 1st edition, Darmstadt, 1999. \\ **[Feist 2
- Improving thermal bridges and airtightness in existing buildings @planning:refurbishment_with_passive_house_components:thermal_envelope
- kP 21] ]]). The advantages are obvious: there are no problems with cold spots and moisture damage and no complicated and tedious calculations to make, jus... face temperatures in the winter, so that there is no risk of mould growth even behind furniture placed... 1999. Thermal bridge free design; Protocol Volume No. 16 of the Research Group for Cost-effective Pass
- Economic analysis for the retrofit of a detached single family house to the EnerPHit standard
- * financial assessment period = 30 years, * no Residual Value, * heating and hot water price... t €36/ml: €1670, and 5 inlets €30/u = €150). * No specific treatment of existing render (good stren... matically cheaper than low energy alternatives if no effort is made to simplify solutions and implemen
- Step-by-step Retrofits towards EnerPHit Standard in social housing in Spain
- retrofits are performed by small companies where no qualified technicians are involved. As a result, ... and the execution quality is deficient. Usually, no quality control is done at the end of the works, ... ted to works made on the flat from the inside and no common areas have been affected, neighbourhood as
- Overall retrofit plan for step-by-step retrofits to EnerPHit Standard
- rt with a variant for the existing building, with no or probably poor insulation, poor windows, ventil... preliminary steps you only enter “0” to indicate no PV modules have yet been installed. Solar thermal
- Step-by-step deep retrofit and building integrated façade/roof on a 'million program' house
- er similar buildings could fall to the level that no subventions would be needed for such projects to ... certified by the Passive House Institute. It has no special control and only ensures fresh air supply
- Component Award 2016: Affordable ventilation solutions for retrofits
- s. In such cases, the ventilation device takes up no additional area inside. Façade integration is an
- Refurbishment with Passive House components - introduction
- mal final state, were addressed in Research Group No. 39 “Step-by-step modernisation using Passive Hou
- Passive House refurbishment - thermal envelope
- ks:insulation_prevents_structural_damage_evidence_no.4_measurements_in_a_retrofit|Thermal protection i
- Airtightness and airtightness measurement @planning:refurbishment_with_passive_house_components:thermal_envelope
- d facilitates the test in old buildings for which no detail plans are available. Beams, visible rafte
- Floor Replacement: Svartbäcksvägen @planning:refurbishment_with_passive_house_components:thermal_envelope
- ation of a MVHR system, will ensure that there is no danger from the radioactive gas in the house. On
- Insulation measures for the external envelope @planning:refurbishment_with_passive_house_components:thermal_envelope
- or Cost-effective Passive Houses, Protocol Volume No. 24, 1st edition 2004 \\ **[Feist / John / Kah 20