Fulltext results:
- Types of ventilation @planning:building_services:ventilation:basics
- llent air quality is especially essential and can only be achieved if "used" air is regularly replaced b... ranteed and adequate exchange of air in winter is only possible by means of comfort ventilation – this ... ation, adequate air exchange in new buildings can only take place by means of regular purge ventilation.... e)]]. The right level of air humidity is not the only requirement for an adequate exchange of air. Poll
- Air volumes @planning:building_services:ventilation:basics
- Even in single-family houses, the air volumes are only adjusted for longer periods of absence. Neverthel... s with** over-dimensioning**: even modern devices only have a limited control range and feature a certai... e air volumes should be dimensioned to remove not only pollutants but also to get rid of moisture from h... the dimensioning of ducts and installations will only be limited by the costs and the space requirement
- Compact HVAC systems
- mps|compact heat pump units]] {{:picopen:members_only.png?20|}} for Passive House buidlings. Today, a... c technology components are already available but only few of these fully integrated systems are current... esn’t have to be heated then.**}}] Of course, not only Passive Houses can be heated using biomass. Howev... uced fuel is limited. In case of poor efficiency, only a fraction of the buildings in Europe (and also w
- Heating and DHW
- and DHW systems|read more..]] {{:picopen:members_only.png?25}} ===== Heating and DHW systems - compar... s - comparison|read more...]] {{:picopen:members_only.png?20|}} ===== Combustion heat in the Passive H... Passive House|read more...]] {{:picopen:members_only.png?20|}} ===== Biomass heating in Passive House... n Passive Houses|read more...]]{{:picopen:members_only.png?20|}} ===== Heat pumps ===== [[planning:b
- Sound generation, sound dispersion and sound proofing in heat pumps @planning:building_services:heating_and_dhw:heating:heat_pumps
- ation sources in heat pumps]] {{:picopen:members_only.png?25|}} [[planning:building_services:heating_a... ion measures for heat pumps]] {{:picopen:members_only.png?25|}} [[planning:building_services:heating_a... mps:Analysis of sound paths]] {{:picopen:members_only.png?25|}} [[planning:building_services:heating_a... mensioning sound insulation]] {{:picopen:members_only.png?25|}} ===== Summary ===== The analysis of t
- Ventilation
- indoor air quality is indispensable. But this can only be achieved if stale air is exchanged with fresh ... ows twice a day. Ventilation will work accurately only if stale air is removed constantly from the kitch... eded for comfort and for good indoor air quality; only outdoor air will be supplied – no recirculated ai... table indoor conditions. It is essential that not only the planned volume flow rates are achieved in ind
- Comparison of energy performance of ventilation systems using passive vs. active heat recovery @planning:building_services:ventilation
- med to be direct electric. For the active system, only that fraction of its capacity is considered that ... and frost reevaporate. Frost protection is needed only below -19 °C. - Active system with COP values a... y as a passive heat recovery ventilator. There is only one case where active and passive heat recovery h... nsert_active_system_in_phpp|]] {{:picopen:members_only.png?20}} If space heating is provided by the act
- Heating @planning:building_services:heating_and_dhw
- s heating in Passive Houses]] {{:picopen:members_only.png?25|}} [[Planning:building_services:heating_... heating systems in practice]] {{:picopen:members_only.png?25|}} [[sinfonia:Monitoring heat consumption
- Differentiation between Vv and Vn50 values @planning:building_services:ventilation
- s to calculate the ventilation heat losses and is only relevant to determine the minimal air change rate... asurements in Passive Houses]] {{:picopen:members_only.png?nolink&20|}} [[planning:refurbishment_with_p
- Passive House - 6 reasons why you still need opening windows @planning:building_services:ventilation
- s long as you are not building on Mars, there are only a few exceptions). //Saving costs on windows is ... d all night long during winter. In this case, the only negative effect is a slight increase in heating e
- Experience with drain water heat recovery @planning:building_services:heating_and_dhw:experience_with_drain_water_heat_recovery
- y not be possible. * If the heat exchanger is only connected to the hot water connection, high hot w... utilization rate. * If the heat exchanger is only connected to the cold water connection, hardly an
- Basics @planning:building_services:ventilation
- zation of dwelling floor plan configuration for cascade ventilation]] {{:picopen:members_only.png?25|}}
- Heat pumps @planning:building_services:heating_and_dhw:heating
- services systems – Proposed approaches for architects and planners]] {{:picopen:members_only.png?25|}}