Fulltext results:
- Dynamic simulation of a building's thermal performance @planning:calculating_energy_efficiency
- ation node, which are clearly separated from each other. Heat transmitted to interior surfaces is calcula... as heating and/or cooling demands are very low. Another aspect of the whole building approach is the inte... ia involved (e.g. with Navier Stokes), * on the other hand especially in the present boundary condition... nditions that are significantly determined by the other components. This is one of the theses that will b
- Thermal insulation @planning:thermal_protection
- d to be extremely effective in Passive Houses. Another essential principle is "[[basics:building_physics... s well as excessive heat losses. This method is another essential principle assuring a high level of qual... od with the duration of the heating period, or in other terms, multiply the U-value by the heating degree... be compensated for by a corresponding heat gain, otherwise the temperature inside the house will drop.
- Types of ventilation @planning:building_services:ventilation:basics
- than before, like it or not. \\ There are two other things that have changed: - Buildings are more ... entral Europe - and we have heard about this from other Winter cold climates in the world, too. This exp... adon, volatile organic substances, dust, and many other toxic substances** are also present in indoor air... residents of Passive Houses: they don't have to bother about opening the windows at the right time; of
- Baseline study - implementing the Passive House concept in hospitals @planning:non-residential_passive_house_buildings:ph_hospitals
- e level of comfort. As has already been done with other non-residential buildings (such as [[planning:non... iene and energy efforts sometimes complement each other. High-quality insulation on potable water lines a... atures and air exchange rates are greater than in other buildings. \\ As in other Passive House buildings, good insulation means that the type of heat distribu
- Airtightness and airtightness measurement @planning:refurbishment_with_passive_house_components:thermal_envelope
- ng in through the thermal insulation, which would otherwise impair the insulating effect and lead to incr... ding into several zones and test them one after another. It must be made sure that dividing the building ... e not tested at that time can be pressurized by another fan to the same preasure as the tested zone (guar... ightly the suspension has been carried out. Among other things, this stipulation according to [[.:airtigh
- Overall retrofit plan for step-by-step retrofits to EnerPHit Standard @planning:refurbishment_with_passive_house_components
- system, which could not be installed for now. In other multi-family buildings, only one dwelling was imp... ep 3, the roof insulation, the heating system and other measures are implemented to finally reach EnerPHi... picopen:retrofitting_buildings_one_side_after_the_other.png?450|Figure 3: Retrofitting buildings one side after the other / section by section}}] ===== 4 Requirements fo
- Energy balances - Background @planning:calculating_energy_efficiency
- re, the energy flowing out has to be replaced: another heat flow must travel from the outside towards th... ated which reference area they are based on. All other values should be treated with caution – and in ca... r less "suitable" values. * Borsch-Laaks and others have suggested that **the number of occupants** ... measure for the quality of the building.\\ \\ * Others (e.g. the German Engineers Association) prefer t
- Insulation vs. thermal mass @planning:thermal_protection:thermal_protection_works
- process of continued improvement.\\ \\ And on the other hand, this teaches tolerance. No one possesses ab... rtant enough to call into question the dignity of other people. Ethical principles are above science. Oh,... al protection and thermal storage complement each other ===== Both are described by the basic equation f... s, in semi-conductor devices, brake pads and many others can be calculated in good correlation with measu
- Comparison of in-situ measurements and hygrothermal simulations of four different interior insulation systems @planning:thermal_protection:thermal_protection_works:comparison_of_in_situ_measurements_and_hygrothermal_simulations_of_four_different_interior_insulation_systems
- ====== Comparison of in-situ measurements and hygrothermal simulations of four different interior insulat... _works:comparison_of_in_situ_measurements_and_hygrothermal_simulations_of_four_different_interior_insulat... _works:comparison_of_in_situ_measurements_and_hygrothermal_simulations_of_four_different_interior_insulat... _works:comparison_of_in_situ_measurements_and_hygrothermal_simulations_of_four_different_interior_insulat
- Introduction: Retail stores as Passive Houses @planning:non-residential_passive_house_buildings
- n any specific, currently planned use, but rather other future uses should also be taken into account to ... ole here. Much greater savings can be realised in other areas. This will be discussed below in brief, aft... or lighting, and the amount may be even higher in other areas. \\ \\ [{{ :picopen:01_pb40_einfuehrung_en_... dings often still have single glazing.**}}] Like other efficiency measures, thermal protection has playe
- Component Award 2016: Affordable ventilation solutions for retrofits @planning:refurbishment_with_passive_house_components
- ific floor plan. Active overflow elements are another interesting option for air distribution (Figure 1... ral dwelling ventilation systems in space that is otherwise unused, such as in ceilings or integrated in ... nts meant to be seen** For building retrofits, another good option is components that are meant to be se... tors to be efficient in actual operation as well. Otherwise, devices with good power efficiency under lab
- Step-by-step Retrofits towards EnerPHit Standard in social housing in Spain @planning:refurbishment_with_passive_house_components
- exist with original components or with changes by other owners. It hampers the search for an integral tec... lation layer; VAND arquitectura}}][{{:picopen:hygrothermal_study_exterior_wall_and_floor_structure_connec... il_step_1_vand_arquitectura.png?500|Figure 4: Hygrothermal study: exterior wall and floor structure conne... ntre, but this can be an additional difficulty in other cases. === 3.2.6 Results === The total energy
- Windows in a step-by-step retrofit @planning:refurbishment_with_passive_house_components
- . In addition, building users may not wish to be bothered further. Often, there simply is not enough capi... ged; the process goes quickly, and users are not bothered much. There are, however, high follow-up costs.... frame can easily have insulation added to it. All other solutions turned out to be detrimental: If the fr... h as those from Iso Chemie, Hanno and Illbruck. Another option is self-made hidden parts of the frame mad
- Internal heat gains in relation to living area @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- or practical planning. An additional review using other approaches (e.g. for specific known occupancy, eq... ical accuracies. Comparable statistical data from other countries was not available, unfortunately. Below... on cooker, 0.2 kWh per use \\ ====4 Approach for other electricity applications ==== Here it must be con... not necessary here. These effects compensate each other approximately, therefore a separate investigation
- Don’t save on the insulation @planning:thermal_protection
- of insulation, the more money will be saved. The other features are also positively affected by good ins... e more insulation material won't cost that much – otherwise it won't be possible to increase the insulati... ased on fuel-oil was assumed, but the results for other energy carriers are basically no different.\\ The... ve to be renovated or painted any more often than other facades and the new coat of paint/improvement wil
- Passive House Schools - Boundary Conditions @planning:non-residential_passive_house_buildings:passive_house_schools
- Improving thermal bridges and airtightness in existing buildings @planning:refurbishment_with_passive_house_components:thermal_envelope
- Step-by-step deep retrofit and building integrated façade/roof on a 'million program' house @planning:refurbishment_with_passive_house_components
- Passive House schools – How to go about it @planning:non-residential_passive_house_buildings:passive_house_schools
- Energy use for heating in a well insulated new building @planning:thermal_protection:thermal_protection_works
- Refurbishment with Passive House components - introduction @planning:refurbishment_with_passive_house_components
- Prospects for the modernisation of existing buildings using highly efficient components @planning:refurbishment_with_passive_house_components
- Checklist: Test reports of airtightness measurements @planning:airtight_construction:general_principles
- Comparison of energy performance of ventilation systems using passive vs. active heat recovery @planning:building_services:ventilation
- Passive House - 6 reasons why you still need opening windows @planning:building_services:ventilation
- PHPP - validated and proven in practice @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- The overall heat transfer coefficient or U-value @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- Variant calculations and economic assessment with PHPP 9 @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- Aspects of efficient ventilation in hospitals @planning:non-residential_passive_house_buildings:ph_hospitals
- Insulation measures for the external envelope @planning:refurbishment_with_passive_house_components:thermal_envelope
- Building Integrated Photovoltaics (BIPV) in Step by Step Retrofitting Projects @planning:refurbishment_with_passive_house_components
- Economic analysis for the retrofit of a detached single family house to the EnerPHit standard @planning:refurbishment_with_passive_house_components
- PHPP calculations in hot and humid climates @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- “designPH” plugin for Trimble Sketchup @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- Energy efficiency in cafeterias and commercial kitchens @planning:non-residential_passive_house_buildings:cafeterias_and_commercial_kitchens