Fulltext results:
- Dynamic simulation of a building's thermal performance
- ation node, which are clearly separated from each other. Heat transmitted to interior surfaces is calcula... as heating and/or cooling demands are very low. Another aspect of the whole building approach is the inte... ia involved (e.g. with Navier Stokes), * on the other hand especially in the present boundary condition... nditions that are significantly determined by the other components. This is one of the theses that will b
- Energy balances - Background
- re, the energy flowing out has to be replaced: another heat flow must travel from the outside towards th... ated which reference area they are based on. All other values should be treated with caution – and in ca... volume alone. That is nonsense of course - but other dead volumes can also increase the specific energ... is a difference of up to 26 % in the example, for other examples the difference could even be up to 30%.\
- Internal heat gains in relation to living area @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- or practical planning. An additional review using other approaches (e.g. for specific known occupancy, eq... ical accuracies. Comparable statistical data from other countries was not available, unfortunately. Below... on cooker, 0.2 kWh per use \\ ====4 Approach for other electricity applications ==== Here it must be con... not necessary here. These effects compensate each other approximately, therefore a separate investigation
- PHPP – Passive House Planning Package
- inputs and calculations for various areas. Among other things, the PHPP deals with the following aspects... as one unit including the ventilation system and other mechanical systems. ===== Literature ===== **[[
- PHPP - validated and proven in practice @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- conditions that are significantly different from other calculation procedures (e.g. the energy savings o... n the PHPP and in DIN EN ISO 832. \\ \\ These and other details lead to differences in calculation result
- The overall heat transfer coefficient or U-value @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- uilding elements of the building envelope, or, in other words, all building elements through which heat i... 4. For the certification of Passive Houses in all other countries, the lambda value determined as defined
- Variant calculations and economic assessment with PHPP 9 @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- heets entitled Variants and Comparison along with other innovations. The Variants sheet gives users the o... ir energy demand and affordability in depth.\\ Another tool, the PHeco external calculation tool (integr
- “designPH” plugin for Trimble Sketchup @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- ided. These also allow the components library and other model properties to be edited. \\ \\ |{{:picopen