Fulltext results:
- Thermal insulation
- od with the duration of the heating period, or in other terms, multiply the U-value by the heating degree... be compensated for by a corresponding heat gain, otherwise the temperature inside the house will drop. ... ue of a Passive House wall needs to be quite low; otherwise a considerable portion of this power would be... able are ideal for this. Combined structures with other building materials are possible, and in some case
- Insulation vs. thermal mass @planning:thermal_protection:thermal_protection_works
- process of continued improvement.\\ \\ And on the other hand, this teaches tolerance. No one possesses ab... rtant enough to call into question the dignity of other people. Ethical principles are above science. Oh,... al protection and thermal storage complement each other ===== Both are described by the basic equation f... s, in semi-conductor devices, brake pads and many others can be calculated in good correlation with measu
- Don’t save on the insulation
- of insulation, the more money will be saved. The other features are also positively affected by good ins... e more insulation material won't cost that much – otherwise it won't be possible to increase the insulati... ased on fuel-oil was assumed, but the results for other energy carriers are basically no different.\\ The... ve to be renovated or painted any more often than other facades and the new coat of paint/improvement wil
- Energy use for heating in a well insulated new building @planning:thermal_protection:thermal_protection_works
- ldings in Germany; approx. 160 kWh/(m²yr).\\ All other values: energy use for heating measured in the te... e Passive House in Darmstadt Kranichstein, on the other hand, shows a stable consumption of as little as ... ement results:Energy use – measurement results]]. Other documented Passive House projects can be found in
- Outdoor thermography @planning:thermal_protection:thermal_protection_works
- eat only travels a short distance the masonry. In other areas, furniture is positioned along the external... what covered by the front edge of the insulation; otherwise the effect would be even more obvious.\\ \\
- Types of glazing and their specific values @planning:thermal_protection:windows
- or windows has advanced more rapidly than for any other building component. The overall heat transfer coe... course, this result can only be achieved with all other Passive House criteria being fufilled at the same
- Windows
- cold surfaces. Highly insulated windows, on the other hand, will make an active contribution to increas
- PHI window certification: previous success and new climate zones @planning:thermal_protection:windows:window_certification
- have a worse U-value than the glazing and, on the other hand, no direct solar gains are possible through