• skip to content

User Tools

  • Log In

Site Tools

  • Recent Changes
  • Media Manager
  • Sitemap
You are here: Cloud Plugin » other

other

Search

You can find the results of your search below.

Starts with
  • Exact match
  • Starts with
  • Ends with
  • Contains
@planning
  • Any namespace
  • planning:refurbishment_with_passive_house_components (11)
  • planning:building_services (9)
  • planning:calculating_energy_efficiency (8)
  • planning:thermal_protection (8)
  • planning:non-residential_passive_house_buildings (7)
  • planning:airtight_construction (4)
  • planning:planning (1)
  • planning:summer_comfort (1)
Any time
  • Any time
  • Past week
  • Past month
  • Past year
Sort by hits
  • Sort by hits
  • Sort by last modified

Matching pagenames:

  • Comparison of in-situ measurements and hygrothermal simulations of four different interior insulation systems

Fulltext results:

Dynamic simulation of a building's thermal performance @planning:calculating_energy_efficiency
11 Hits, Last modified: 5 years ago
ation node, which are clearly separated from each other. Heat transmitted to interior surfaces is calcula... ia involved (e.g. with Navier Stokes), * on the other hand especially in the present boundary condition... nditions that are significantly determined by the other components. This is one of the theses that will b... on the component "window" itself, but also on the other components of the room (in particular their insul
Overall retrofit plan for step-by-step retrofits to EnerPHit Standard @planning:refurbishment_with_passive_house_components
9 Hits, Last modified: 6 years ago
system, which could not be installed for now. In other multi-family buildings, only one dwelling was imp... ep 3, the roof insulation, the heating system and other measures are implemented to finally reach EnerPHi... picopen:retrofitting_buildings_one_side_after_the_other.png?450|Figure 3: Retrofitting buildings one side after the other / section by section}}] ===== 4 Requirements fo
Thermal insulation @planning:thermal_protection
9 Hits, Last modified: 4 years ago
od with the duration of the heating period, or in other terms, multiply the U-value by the heating degree... be compensated for by a corresponding heat gain, otherwise the temperature inside the house will drop. ... ue of a Passive House wall needs to be quite low; otherwise a considerable portion of this power would be... able are ideal for this. Combined structures with other building materials are possible, and in some case
Baseline study - implementing the Passive House concept in hospitals @planning:non-residential_passive_house_buildings:ph_hospitals
9 Hits, Last modified: 2 years ago
e level of comfort. As has already been done with other non-residential buildings (such as [[planning:non... iene and energy efforts sometimes complement each other. High-quality insulation on potable water lines a... atures and air exchange rates are greater than in other buildings. \\ As in other Passive House buildings, good insulation means that the type of heat distribu
Insulation vs. thermal mass @planning:thermal_protection:thermal_protection_works
9 Hits, Last modified: 3 years ago
process of continued improvement.\\ \\ And on the other hand, this teaches tolerance. No one possesses ab... rtant enough to call into question the dignity of other people. Ethical principles are above science. Oh,... al protection and thermal storage complement each other ===== Both are described by the basic equation f... s, in semi-conductor devices, brake pads and many others can be calculated in good correlation with measu
Types of ventilation @planning:building_services:ventilation:basics
9 Hits, Last modified: 2 years ago
than before, like it or not. \\ There are two other things that have changed: - Buildings are more ... entral Europe - and we have heard about this from other Winter cold climates in the world, too. This exp... adon, volatile organic substances, dust, and many other toxic substances** are also present in indoor air... tems, the kitchen, bathroom and toilet as well as other areas with high humidity and odours are ventilate
Energy balances - Background @planning:calculating_energy_efficiency
8 Hits, Last modified: 5 years ago
ated which reference area they are based on. All other values should be treated with caution – and in ca... r less "suitable" values. * Borsch-Laaks and others have suggested that **the number of occupants** ... measure for the quality of the building.\\ \\ * Others (e.g. the German Engineers Association) prefer t... volume alone. That is nonsense of course - but other dead volumes can also increase the specific energ
Introduction: Retail stores as Passive Houses @planning:non-residential_passive_house_buildings
7 Hits, Last modified: 7 years ago
n any specific, currently planned use, but rather other future uses should also be taken into account to ... ole here. Much greater savings can be realised in other areas. This will be discussed below in brief, aft... or lighting, and the amount may be even higher in other areas. \\ \\ [{{ :picopen:01_pb40_einfuehrung_en_... dings often still have single glazing.**}}] Like other efficiency measures, thermal protection has playe
Airtightness and airtightness measurement @planning:refurbishment_with_passive_house_components:thermal_envelope
6 Hits, Last modified: 12 months ago
ng in through the thermal insulation, which would otherwise impair the insulating effect and lead to incr... ightly the suspension has been carried out. Among other things, this stipulation according to [[.:airtigh... ork of gaps and hollow spaces containing air – in other words, the brickwork is an air conducting layer. ... ght connection of these airtight layers with each other. Since the frame and plaster can move in relatio
Internal heat gains in relation to living area @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
5 Hits, Last modified: 3 years ago
or practical planning. An additional review using other approaches (e.g. for specific known occupancy, eq... ical accuracies. Comparable statistical data from other countries was not available, unfortunately. Below... on cooker, 0.2 kWh per use \\ ====4 Approach for other electricity applications ==== Here it must be con... not necessary here. These effects compensate each other approximately, therefore a separate investigation
Don’t save on the insulation @planning:thermal_protection
4 Hits, Last modified: 5 years ago
of insulation, the more money will be saved. The other features are also positively affected by good ins... e more insulation material won't cost that much – otherwise it won't be possible to increase the insulati... ased on fuel-oil was assumed, but the results for other energy carriers are basically no different.\\ The... ve to be renovated or painted any more often than other facades and the new coat of paint/improvement wil
Supplying Passive Houses with sustainable energy @planning:building_services:heating_and_dhw
4 Hits, Last modified: 11 years ago
ic meters of wood can be cut for this purpose. No other renewable energy sources are available (in this e... ly. They are not, however, sustainable, since the other 90 houses still need fossil fuels for heating. Th... ence for individual buildings are ill advised for other reasons. Even for an only moderately efficient, f... uction relative to its treated floor area. On the other hand, even in central Europe, it is difficult for
Passive House Schools - Boundary Conditions @planning:non-residential_passive_house_buildings:passive_house_schools
4 Hits, Last modified: 4 years ago
nd path to go - and that will also reduce all the other indoor air pullutants to secure levels (for examp... e greatly reduced outside of these times, because otherwise there will be very high electricity consumpti... density, the CO<sub>2</sub> content of the air or other representative **air quality indicator** can be b... tion can be easily measured; and is correlated to other indoor pollution substances e.g. Radon. With a ve
Improving thermal bridges and airtightness in existing buildings @planning:refurbishment_with_passive_house_components:thermal_envelope
4 Hits, Last modified: 6 years ago
the 50s and 60s, and also for those in the 70s as other materials were also used (e.g. pumice), but the r... modernisation approaches hardly differ from each other. In the years up to 1950, wood beam ceilings were... basement ceiling, later on increasingly also for other floors except for the topmost ceiling. The typica... f each of the individual component layers to each other, it will not be possible to achieve an adequate s
Component Award 2016: Affordable ventilation solutions for retrofits @planning:refurbishment_with_passive_house_components
3 Hits, Last modified: 6 years ago
ral dwelling ventilation systems in space that is otherwise unused, such as in ceilings or integrated in ... tors to be efficient in actual operation as well. Otherwise, devices with good power efficiency under lab... t, components, duct network, installation and any other costs, such as an encasement or suspended ceiling
Step-by-step Retrofits towards EnerPHit Standard in social housing in Spain @planning:refurbishment_with_passive_house_components
3 Hits, Last modified: 9 years ago
Why build an airtight house? – Leakage problems @planning:airtight_construction:general_principles
3 Hits, Last modified: 6 years ago
Passive House schools – How to go about it @planning:non-residential_passive_house_buildings:passive_house_schools
3 Hits, Last modified: 8 years ago
Energy use for heating in a well insulated new building @planning:thermal_protection:thermal_protection_works
3 Hits, Last modified: 6 years ago
Component guidelines for cost-optimal Passive Houses and EnerPHit retrofits
2 Hits, Last modified: 8 years ago
Pressure Loss Calculation Tool
2 Hits, Last modified: 2 years ago
PHPP – Passive House Planning Package @planning:calculating_energy_efficiency
2 Hits, Last modified: 14 months ago
Refurbishment with Passive House components - introduction @planning:refurbishment_with_passive_house_components
2 Hits, Last modified: 7 years ago
Prospects for the modernisation of existing buildings using highly efficient components @planning:refurbishment_with_passive_house_components
2 Hits, Last modified: 7 years ago
Step-by-step deep retrofit and building integrated façade/roof on a 'million program' house @planning:refurbishment_with_passive_house_components
2 Hits, Last modified: 5 years ago
Windows in a step-by-step retrofit @planning:refurbishment_with_passive_house_components
2 Hits, Last modified: 9 years ago
Checklist: Test reports of airtightness measurements @planning:airtight_construction:general_principles
2 Hits, Last modified: 2 years ago
Comparison of energy performance of ventilation systems using passive vs. active heat recovery @planning:building_services:ventilation
2 Hits, Last modified: 2 years ago
PHPP - validated and proven in practice @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
2 Hits, Last modified: 13 months ago
The overall heat transfer coefficient or U-value @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
2 Hits, Last modified: 11 years ago
Aspects of efficient ventilation in hospitals @planning:non-residential_passive_house_buildings:ph_hospitals
2 Hits, Last modified: 3 years ago
Insulation measures for the external envelope @planning:refurbishment_with_passive_house_components:thermal_envelope
2 Hits, Last modified: 7 years ago
Outdoor thermography @planning:thermal_protection:thermal_protection_works
2 Hits, Last modified: 4 years ago
Types of glazing and their specific values @planning:thermal_protection:windows
2 Hits, Last modified: 3 years ago
Tools
1 Hits, Last modified: 12 months ago
Compact HVAC systems @planning:building_services
1 Hits, Last modified: 5 years ago
Heating and DHW @planning:building_services
1 Hits, Last modified: 7 years ago
Ventilation @planning:building_services
1 Hits, Last modified: 20 months ago
Thermal protection and modernisation of existing buildings @planning:planning
1 Hits, Last modified: 6 years ago
Economic analysis for the retrofit of a detached single family house to the EnerPHit standard @planning:refurbishment_with_passive_house_components
1 Hits, Last modified: 6 years ago
Summer Comfort Guideline @planning:summer_comfort
1 Hits, Last modified: 3 years ago
Windows @planning:thermal_protection
1 Hits, Last modified: 5 years ago
Airtightness test @planning:airtight_construction:general_principles
1 Hits, Last modified: 7 years ago
General principles for improving airtightness @planning:airtight_construction:general_principles
1 Hits, Last modified: 10 years ago
Passive House - 6 reasons why you still need opening windows @planning:building_services:ventilation
1 Hits, Last modified: 6 years ago
The ventilation system – there is no alternative @planning:building_services:ventilation
1 Hits, Last modified: 3 years ago
“designPH” plugin for Trimble Sketchup @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
1 Hits, Last modified: 7 years ago
Variant calculations and economic assessment with PHPP 9 @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
1 Hits, Last modified: 6 years ago
Energy efficiency in cafeterias and commercial kitchens @planning:non-residential_passive_house_buildings:cafeterias_and_commercial_kitchens
1 Hits, Last modified: 3 years ago
Ventilation in commercial kitchens @planning:non-residential_passive_house_buildings:cafeterias_and_commercial_kitchens
1 Hits, Last modified: 18 months ago
Air volumes @planning:building_services:ventilation:basics
1 Hits, Last modified: 6 years ago
PHI window certification: previous success and new climate zones @planning:thermal_protection:windows:window_certification
1 Hits, Last modified: 3 years ago

Page Tools

  • Old revisions
  • Backlinks
  • Back to top
Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki
    DE EN