Fulltext results:
- Overall retrofit plan for step-by-step retrofits to EnerPHit Standard @planning:refurbishment_with_passive_house_components
- system, which could not be installed for now. In other multi-family buildings, only one dwelling was imp... ep 3, the roof insulation, the heating system and other measures are implemented to finally reach EnerPHi... picopen:retrofitting_buildings_one_side_after_the_other.png?450|Figure 3: Retrofitting buildings one side after the other / section by section}}] ===== 4 Requirements fo
- Dynamic simulation of a building's thermal performance @planning:calculating_energy_efficiency
- ation node, which are clearly separated from each other. Heat transmitted to interior surfaces is calcula... ia involved (e.g. with Navier Stokes), * on the other hand especially in the present boundary condition... nditions that are significantly determined by the other components. This is one of the theses that will b... on the component "window" itself, but also on the other components of the room (in particular their insul
- Baseline study - implementing the Passive House concept in hospitals @planning:non-residential_passive_house_buildings:ph_hospitals
- e level of comfort. As has already been done with other non-residential buildings (such as [[planning:non... iene and energy efforts sometimes complement each other. High-quality insulation on potable water lines a... atures and air exchange rates are greater than in other buildings. \\ As in other Passive House buildings, good insulation means that the type of heat distribu
- Types of ventilation @planning:building_services:ventilation:basics
- than before, like it or not. \\ There are two other things that have changed: - Buildings are more ... entral Europe - and we have heard about this from other Winter cold climates in the world, too. This exp... adon, volatile organic substances, dust, and many other toxic substances** are also present in indoor air... tems, the kitchen, bathroom and toilet as well as other areas with high humidity and odours are ventilate
- Introduction: Retail stores as Passive Houses @planning:non-residential_passive_house_buildings
- n any specific, currently planned use, but rather other future uses should also be taken into account to ... ole here. Much greater savings can be realised in other areas. This will be discussed below in brief, aft... or lighting, and the amount may be even higher in other areas. \\ \\ [{{ :picopen:01_pb40_einfuehrung_en_... dings often still have single glazing.**}}] Like other efficiency measures, thermal protection has playe
- Thermal insulation @planning:thermal_protection
- od with the duration of the heating period, or in other terms, multiply the U-value by the heating degree... able are ideal for this. Combined structures with other building materials are possible, and in some case... s typical for Germany; interest rates may vary in other countries). Add to this the 2500 € spent on the s... golden end" in Wall Street terms. - All the **other advantages** associated with improved thermal pro
- Insulation vs. thermal mass @planning:thermal_protection:thermal_protection_works
- process of continued improvement.\\ \\ And on the other hand, this teaches tolerance. No one possesses ab... rtant enough to call into question the dignity of other people. Ethical principles are above science. Oh,... al protection and thermal storage complement each other ===== Both are described by the basic equation f... l and measured values conform so well with each\\ other that deviations are not noticeable on this scale
- Energy balances - Background @planning:calculating_energy_efficiency
- ated which reference area they are based on. All other values should be treated with caution – and in ca... volume alone. That is nonsense of course - but other dead volumes can also increase the specific energ... is a difference of up to 26 % in the example, for other examples the difference could even be up to 30%.\... the staircase or inner wall cross-section or some other non-useable space. It is part of the constructio
- Internal heat gains in relation to living area @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- or practical planning. An additional review using other approaches (e.g. for specific known occupancy, eq... ical accuracies. Comparable statistical data from other countries was not available, unfortunately. Below... on cooker, 0.2 kWh per use \\ ====4 Approach for other electricity applications ==== Here it must be con... not necessary here. These effects compensate each other approximately, therefore a separate investigation
- Airtightness and airtightness measurement @planning:refurbishment_with_passive_house_components:thermal_envelope
- ightly the suspension has been carried out. Among other things, this stipulation according to [[.:airtigh... ork of gaps and hollow spaces containing air – in other words, the brickwork is an air conducting layer. ... ght connection of these airtight layers with each other. Since the frame and plaster can move in relation to each other as a result of the different thermal expansion co
- Supplying Passive Houses with sustainable energy @planning:building_services:heating_and_dhw
- ic meters of wood can be cut for this purpose. No other renewable energy sources are available (in this e... ly. They are not, however, sustainable, since the other 90 houses still need fossil fuels for heating. Th... ence for individual buildings are ill advised for other reasons. Even for an only moderately efficient, f... uction relative to its treated floor area. On the other hand, even in central Europe, it is difficult for
- Improving thermal bridges and airtightness in existing buildings @planning:refurbishment_with_passive_house_components:thermal_envelope
- the 50s and 60s, and also for those in the 70s as other materials were also used (e.g. pumice), but the r... modernisation approaches hardly differ from each other. In the years up to 1950, wood beam ceilings were... basement ceiling, later on increasingly also for other floors except for the topmost ceiling. The typica... f each of the individual component layers to each other, it will not be possible to achieve an adequate s
- Step-by-step Retrofits towards EnerPHit Standard in social housing in Spain @planning:refurbishment_with_passive_house_components
- exist with original components or with changes by other owners. It hampers the search for an integral tec... ntre, but this can be an additional difficulty in other cases. === 3.2.6 Results === The total energy ... ive high-efficiency energy retrofit together with other measures to reach the EnerPHit standard. These mo
- Don’t save on the insulation @planning:thermal_protection
- of insulation, the more money will be saved. The other features are also positively affected by good ins... ased on fuel-oil was assumed, but the results for other energy carriers are basically no different.\\ The... ve to be renovated or painted any more often than other facades and the new coat of paint/improvement wil
- Why build an airtight house? – Leakage problems @planning:airtight_construction:general_principles
- ut they must be implemented independently of each other: * A well-insulating building component does... ouses - but there seem to be such problems within other ambitious low energy projects. Yes, it's difficul... o'll get higher risks for bad performance. On the other side, it's not much an effort to learn how to dei
- Passive House Schools - Boundary Conditions @planning:non-residential_passive_house_buildings:passive_house_schools
- Energy use for heating in a well insulated new building @planning:thermal_protection:thermal_protection_works
- Refurbishment with Passive House components - introduction @planning:refurbishment_with_passive_house_components
- Prospects for the modernisation of existing buildings using highly efficient components @planning:refurbishment_with_passive_house_components
- Step-by-step deep retrofit and building integrated façade/roof on a 'million program' house @planning:refurbishment_with_passive_house_components
- Comparison of energy performance of ventilation systems using passive vs. active heat recovery @planning:building_services:ventilation
- PHPP - validated and proven in practice @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- The overall heat transfer coefficient or U-value @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- Aspects of efficient ventilation in hospitals @planning:non-residential_passive_house_buildings:ph_hospitals
- Insulation measures for the external envelope @planning:refurbishment_with_passive_house_components:thermal_envelope
- Component Award 2016: Affordable ventilation solutions for retrofits @planning:refurbishment_with_passive_house_components
- Economic analysis for the retrofit of a detached single family house to the EnerPHit standard @planning:refurbishment_with_passive_house_components
- Checklist: Test reports of airtightness measurements @planning:airtight_construction:general_principles
- Passive House - 6 reasons why you still need opening windows @planning:building_services:ventilation
- “designPH” plugin for Trimble Sketchup @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- Variant calculations and economic assessment with PHPP 9 @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- Ventilation in commercial kitchens @planning:non-residential_passive_house_buildings:cafeterias_and_commercial_kitchens