• skip to content

User Tools

  • Log In

Site Tools

  • Recent Changes
  • Media Manager
  • Sitemap
You are here: Cloud Plugin » out

out

Search

You can find the results of your search below.

Ends with
  • Exact match
  • Starts with
  • Ends with
  • Contains
@basics:building_physics_-_basics
  • Any namespace
  • basics:building_physics_-_basics:thermal_bridges (5)
  • basics:building_physics_-_basics:thermal_comfort (3)
Any time
  • Any time
  • Past week
  • Past month
  • Past year
Sort by hits
  • Sort by hits
  • Sort by last modified

Fulltext results:

Heating load in Passive Houses
5 Hits, Last modified: 6 years ago
higher than 15 kWh/(m²a)) is negligible – only about 10% of the energy used in conventional buildings.... t can be distributed via the fresh air system without any additional costs is limited. For a house with... for the measured daily mean heating loads below about 0 °C. This correlation was correctly explained in... eating load results simply cannot be obtained without taking into account solar gains, particularly in
Special features and characteristics of components in contact with the ground @basics:building_physics_-_basics:thermal_bridges:tbcalculation:ground_contact
4 Hits, Last modified: 3 years ago
sted that on average the surface temperature is about 1 K higher than the outdoor air temperature. Thus... mass. An exterior wall which absorbs heat throughout the day releases it again during cooler temperatu... e for the monthly method, this effect is averaged out because the number of charging phases are the sam... rneath - skirt insulation, i.e. floor slab without insulation, but with a strip of insulation all ar
What defines thermal bridge free design?
3 Hits, Last modified: 3 years ago
with a few simple changes in the details and without incurring high costs. However, this must be **rec... within the insulation layers using a pencil, without a break. The following figure illustrates this pr... terior envelope can be outlined with a pencil without lifting the pencil from the paper.}}] ===== Re
Definition and effects of thermal bridges @basics:building_physics_-_basics:thermal_bridges
3 Hits, Last modified: 3 years ago
and construction manager don't have to **worry about cold and damp spots any more ** - and less effort... from a calculation in (DIN EN ISO 10211) - without taking into account in case of [[basics:building... perature higher than the dewpoint temperature without condensation being present. For a building physic... rules for engineering practice (DIN 4108-2) rule out the risk of mould near thermal bridges if the min
Adaptive versus Heat Balance Comfort Models @basics:building_physics_-_basics:thermal_comfort
3 Hits, Last modified: 6 years ago
re and indoor comfort temperature is assumed, without any reference to possible limits of validity. Thi... ure) is documented for 116 buildings with and without air-conditioning. 2 of these 116 preferred temper... ** in naturally ventilated buildings were often about 0.4 to 0.5 m/s, much higher than in air-condition... o-called **range effect**. [McIntyre 1980] points out that, when exposed to a range of stimuli and equi
Interior walls on floor slabs @basics:building_physics_-_basics:thermal_bridges:tbcalculation:examples
3 Hits, Last modified: 4 years ago
slabs are often calculated two-dimensionally without the influence of the ground. The result will be s... floor slab"]]. For this, first a conductance without taking the interior wall into account is determin... e the difference in the conductances with and without the interior wall. Another advantage is that the
Thermal comfort
2 Hits, Last modified: 3 years ago
e energy to achieve a comfortable temperature without the help of either a conventional heating or air ... s keep the desired warmth in and undesirable heat out. This means that the floor and all interior walls
Thermal comfort parameters @basics:building_physics_-_basics:thermal_comfort
2 Hits, Last modified: 5 years ago
n result: There is no draft in the room, even without a heating element under the window. * If t... se all of the comfort criteria are fulfilled, without the need for a compensatory radiation heating sur... mple group of inhabitants revealed good remarks about well insulated buildings. [ 4 ] \\ \\ ===== See
Basic principle for calculating thermal bridges @basics:building_physics_-_basics:thermal_bridges:tbcalculation
2 Hits, Last modified: 3 years ago
hat the linear reference is adhered to all throughout. If interior references are used in the context o... sponding place for any temperature difference without the need for further heat flow simulations. With ... the $f_{Rsi}$ factor, conclusions can be drawn about any potential condensation formation and mould gr
Thermal Bridges Catalogue @basics:building_physics_-_basics:thermal_bridges
1 Hits, Last modified: 10 months ago
thickness, and thermal conductivity. You can find out more about this Thermal Bridges Tool [[:planning:thermal_bridge_tool|here]]. {{:picopen:sinfonia_eu_p... des and Aids click [[planning:tools|here]] to go to the "Tool" Further articles about [[.:start|]]
Local thermal comfort @basics:building_physics_-_basics:thermal_comfort
1 Hits, Last modified: 6 years ago
comfort criteria have been ideally fulfilled, without the need for a compensating heating surface. That

Page Tools

  • Old revisions
  • Backlinks
  • Back to top
Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki
    DE EN