Fulltext results:
- Dynamic simulation of a building's thermal performance
- y introduced in the natural sciences. It goes without saying that discretization errors and numerical e... el: even the parameter studies, which are carried out in [Feist 1994] with great effort, are not suitab... ildings, there is a widespread basic skepticism about simulation: Many practitioners only trust statements about the annual heating requirements of houses if they
- Energy balances - Background
- iciency:Energy balances - Background#Discussion about the purpose of heating]]).\\ \\ |{{ :picopen:bila... s ===== Let us look at a heat flow which travels out of the balance area through the envelope, e.g. wa... in living comfort. Therefore, the energy flowing out has to be replaced: another heat flow must trave... ouse Planning Package]]).\\ \\ ==== Discussion about the purpose of heating ==== Does the purpose of
- PHPP – Passive House Planning Package
- ining_thermal_comfort_in_summer_for_buildings_without_active_cooling|passive cooling tool]] )\\ * Annua... to compare components of different qualities without great effort and thus optimise the specific const... th conventional calculation methods. (Read more about this in the section [[.:phpp_-_the_passive_house_... delling tool (SketchUP plugin) \\ for the PHPP is out now. \\ \\ [[.:phpp_-_the_passive_house_planning
- Internal heat gains in relation to living area @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- broken down according to households with and without hot water generation. A straight line can be fitt... \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ The PHI points out that it is not permissible at all to use such hig... efore only allows limited statements to be made about electricity consumption during the lifetime of th... fore a separate investigation will not be carried out for small single-family houses. ===8.1 Circula
- “designPH” plugin for Trimble Sketchup @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- c space heat demand to be calculated quickly, without the need for much direct data-entry. The advantag... ea of the building’s energy performance, and rule out poorly performing design options, before exportin... ple energy balance within the tool and warnings about high-levels of glazing that would lead to overhea
- PHPP calculations in hot and humid climates @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- hich the Passive House concept can be reached without the need for active cooling the frequency of over
- Variant calculations and economic assessment with PHPP 9 @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- ing the PHPP project file once it had been filled out, unless users had advanced Excel programming skil... w of error and warning messages and suggestions about the reasons why calculation results are missing. ... ackage|Overview]] of all articles on Passipedia about PHPP [[phi_publications:international_passive_h