Fulltext results:
- Airtightness measurements in Passive Houses @planning:airtight_construction
- ive Houses ====== ===== Instructions for carrying out measurements ===== Airtightness measurements in Passive House buildings are to be carried out uniformly worldwide according to ISO 9972, method... erence volume for passive houses is to be carried out according to the procedure listed below which is ... for each room. The calculation should be carried out in accordance with detailed rules given in the [[
- Overall retrofit plan for step-by-step retrofits to EnerPHit Standard @planning:refurbishment_with_passive_house_components
- –Europe (IEE) programme, deep renovations carried out step by step have been the focus of a consortium ... ctor is significant: According to a study carried out by the German Federal Institute for Research on B... ?750 | Figure 1: EuroPHit case study projects}}] Out of 20 pilot projects started within EuroPHit, 11 ... on process ===== If energy retrofits are carried out in several individual consecutive steps, then pre
- Thermal protection and modernisation of existing buildings @planning:planning
- s assumed that a majority of retrofits is carried out partially, often single measures only, and buildi... c planning or quality assurance is rarely carried out in such instances. In many countries, single meas... nce of the investor or building owner and carried out by a contractor with a more or less moderate know... asure of step-by-step retrofits should be carried out according to high quality standards and a sound r
- Refurbishment with Passive House components - introduction @planning:refurbishment_with_passive_house_components
- terature|[AKKP-32] ]]. The challenges of carrying out individual renovation measures and ways to achiev... prehensive metrological examinations were carried out by the Passive House Institute, the results of wh... \\ constructions alike. If it is properly carried out, the facade\\ will not need to be renovated again... that it would be practically impossible to carry out “subsequent improvement“ with justifiable effort:
- Insulation vs. thermal mass @planning:thermal_protection:thermal_protection_works
- : * For normal building components, it turns out that to a great extent, the heat storage effect already averages out over a period of a few days (see the explanation ... ings using Fourier's Law, the Passive House turns out to be a particularly energy-conserving solution f... w of energy for the heat capacity can be averaged out from the energy balance, because the same amount
- Energy balances - Background @planning:calculating_energy_efficiency
- s ===== Let us look at a heat flow which travels out of the balance area through the envelope, e.g. wa... in living comfort. Therefore, the energy flowing out has to be replaced: another heat flow must trave... t the specific values, it is often easier to find out the absolute annual energy demand or the annual e... t what happens when the children grow up and move out? This is not suitable as a measure for the quali
- Step-by-step Retrofits towards EnerPHit Standard in social housing in Spain @planning:refurbishment_with_passive_house_components
- shment Examples in Spain ===== The works carried out within the European project EuroPHit helped us to... f the existing building. The possibility to carry out the works without being determined by third parti... ness works between neighbouring flats are carried out. \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ === 3.... se cannot be specified since they will be carried out at the end of each component’s life cycle. The h
- Airtightness and airtightness measurement @planning:refurbishment_with_passive_house_components:thermal_envelope
- ticularly large, the pressure test can be carried out using several blower fans. In accordance with the... g the measurement it is always advisable to carry out a series of negative AND excess pressures so that... of how airtightly the suspension has been carried out. Among other things, this stipulation according t... construction details should be as simple to carry out as possible * preferably **large uniform** are
- Dynamic simulation of a building's thermal performance @planning:calculating_energy_efficiency
- el: even the parameter studies, which are carried out in [Feist 1994] with great effort, are not suitab... luences such as different indoor climates average out. To do this, however, the buildings must be suffi... nd 1989]) such measurements were actually carried out in settlements with more than 18 similar resident... after all, some of the model validations carried out stem from this work. From the considerations so
- Airtight construction
- | In winter cool areas, air flows from the inside out cause a moisture problem| \\ Indoor air has a h... climate, indoor air is cooled during flow inside-out (called exfiltration). The colder air can not kee... tightness_measurements_in_passive_houses|Carrying out airtightness measurements in Passive Houses]] [[
- Windows in a step-by-step retrofit @planning:refurbishment_with_passive_house_components
- nsulation added to it. All other solutions turned out to be detrimental: If the frame is installed deep... l costs, and sealing off the resulting bays turns out to be difficult. In addition, the jury for the 20... to the outside; the guide rails are then farther out and do not have any significant thermal bridge ef
- General principles for improving airtightness @planning:airtight_construction:general_principles
- a planning task**. Craftsman can only carry this out in an airtight manner if it has been thoroughly d... the other, this won’t stop the water from leaking out! It is essential that the concept for airtightne... ions. This must be carefully planned and carried out especially at the connections. Passive House arc
- Passive House swimming pools @planning:non-residential_passive_house_buildings:swimming_pools
- ced operating costs. A baseline study was carried out in 2009 to assess the energy saving potentials of... rent publications from the early research carried out by the Passive House Intitute regarding basic pri... concepts developed in the baseline study carried out by the Passive House Institute. In order to verif
- Airtightness Measurement of High-Rise Buildings @planning:airtight_construction
- Institute (PHI) has produced a guide for carrying out airtightness measurements in high-rise buildings.... circumstances. In order to still be able to carry out the measurement in a high-rise building, practica
- Economic analysis for the retrofit of a detached single family house to the EnerPHit standard @planning:refurbishment_with_passive_house_components
- e variability. We can use the phEco model to find out if investing in EnerPHit is robust, given uncerta... present value). A sensitivity analysis is carried out with the Crystal Ball Excel Plug-In. \\ Realist
- Comparison of energy performance of ventilation systems using passive vs. active heat recovery @planning:building_services:ventilation
- Passive House - 6 reasons why you still need opening windows @planning:building_services:ventilation
- Internal heat gains in relation to living area @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- Energy efficiency in cafeterias and commercial kitchens @planning:non-residential_passive_house_buildings:cafeterias_and_commercial_kitchens
- Floor Replacement: Svartbäcksvägen @planning:refurbishment_with_passive_house_components:thermal_envelope
- Improving thermal bridges and airtightness in existing buildings @planning:refurbishment_with_passive_house_components:thermal_envelope
- Insulation works – Evidence no.1 "Measurements at a highly insulated wall" @planning:thermal_protection:thermal_protection_works
- Energy use for heating in a well insulated new building @planning:thermal_protection:thermal_protection_works
- Building Integrated Photovoltaics (BIPV) in Step by Step Retrofitting Projects @planning:refurbishment_with_passive_house_components
- Checklist: Test reports of airtightness measurements @planning:airtight_construction:general_principles
- “designPH” plugin for Trimble Sketchup @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- Variant calculations and economic assessment with PHPP 9 @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package