planning:non-residential_passive_house_buildings
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
planning:non-residential_passive_house_buildings [2022/05/31 15:04] – [Passive House Laboratories] yaling.hsiao@passiv.de | planning:non-residential_passive_house_buildings [2024/04/19 10:52] (current) – [Passive House swimming pools] jgrovesmith | ||
---|---|---|---|
Line 1: | Line 1: | ||
- | ====== Non-residential Passive House buildings ====== | + | ====== Non-residential Passive House buildings ====== |
- | The Passive House Standard allows for extremely high levels of comfort as well as enormous energy savings - not only for residential buildings. The Passive House Standard has been successfully realised in many different types of buildings including offices, hostels, factories, administrative buildings, sports halls, schools and kindergartens. | + | The Passive House Standard allows for extremely high levels of comfort as well as enormous energy savings - not only for residential buildings. The Passive House Standard has been successfully realised in many different types of buildings including offices, hostels, factories, administrative buildings, sports halls, schools and kindergartens. |
- | \\ | + | |
+ | Browse the [[https:// | ||
+ | ---- | ||
===== Passive House schools ===== | ===== Passive House schools ===== | ||
- | + | Passive House school buildings are particularly interesting. Several school buildings have been realised using this standard and experiences gained from their use are now available: The Passive House Standards allows for energy savings of around 75% in comparison with average new school buildings - and of course there is no need for an additional heating or cooling system. The additional investment costs are within reasonable limits.\\ | |
- | + | ||
- | The Passive House Standard is a sensible alternative, | + | |
- | + | ||
- | Passive House school buildings are particularly interesting. Several school buildings have been realised using this standard and experiences gained from their use are now available: The Passive House Standards allows for energy savings of around 75% in comparison with average new school buildings - and of course there is no need for an additional heating or cooling system. The additional investment costs are within reasonable limits. \\ | + | |
\\ | \\ | ||
- | [[planning: | + | [[.: |
- | [[planning: | + | [[.: |
- | [[planning: | + | [[.: |
- | \\ | + | |
- | [{{: | + | |
- | [{{: | + | [{{: |
+ | The Passive House primary school and day nursery in Riedberg Frankfurt a.M. was opened in November 2004 after a construction period of only 14 months. The extra costs for achieving the Passive House Standard were a moderate 5.3 % in comparison with the currently valid EnEV (German energy saving regulations) standard. [[: | ||
+ | Besides great environmental benefits like saving 90 % in heating costs and saving 530 tons of CO< | ||
---- | ---- | ||
- | |||
===== Passive House office buildings ===== | ===== Passive House office buildings ===== | ||
- | **Certification of Passive House office buildings** - Passive House office | + | Office |
- | \\ | + | |
+ | Passive House office building certification is based on a standard occupancy level and corresponding internal gains of 3.5 W/m² (the reference area being the “treated floor area” of the PHPP, not the office area). From the PHI’s experience this value represents a typical average, taking into account an improved efficiency of the equipment used. The reasons why the PHI uses standard values for certification are partly to be able to ensure consistency and also because the use of a building is often not permanent and not always prior known.\\ | ||
+ | [[: | ||
---- | ---- | ||
+ | [{{ : | ||
+ | Lippe-Bad was built as a pilot projet to demonstrate the Passive House concept for indoor swimming pools.}}] | ||
===== Passive House swimming pools ===== | ===== Passive House swimming pools ===== | ||
- | [{{ : | + | Swimming pools are a very energy intensive building typology. The energy demand can be reduced significantly by consistently applying |
+ | Go to the [[.: | ||
- | **Energy efficiency in public indoor swimming pools** \\ | + | The general |
- | + | ||
- | The Passive house concept | + | |
- | [[planning:non-residential_passive_house_buildings:swimming pools: | + | |
- | \\ | + | |
---- | ---- | ||
- | + | [{{ : | |
===== Passive House Hospital ===== | ===== Passive House Hospital ===== | ||
- | [{{ : | ||
Conventional hospitals are among the buildings with very high energy consumption values and incur special demands for the comfort of patients which must be met in a reliable way. The application of the Passive House concept appears extremely interesting in this context. A common misunderstanding is the assumption that energy efficiency efforts are only concerned with the minimisation of the heating demand. The basic idea however is to achieve a significant reduction in the demand for all energy-relevant applications in a building while maintaining the same level of comfort. | Conventional hospitals are among the buildings with very high energy consumption values and incur special demands for the comfort of patients which must be met in a reliable way. The application of the Passive House concept appears extremely interesting in this context. A common misunderstanding is the assumption that energy efficiency efforts are only concerned with the minimisation of the heating demand. The basic idea however is to achieve a significant reduction in the demand for all energy-relevant applications in a building while maintaining the same level of comfort. | ||
- | [[planning: | + | [[.: |
---- | ---- | ||
+ | [{{ : | ||
===== Energy efficiency in cafeterias and commercial kitchens ===== | ===== Energy efficiency in cafeterias and commercial kitchens ===== | ||
+ | Commercial kitchens are one of the most energy-intensive areas of buildings. In addition to cooking, dishes are washed and food is kept cool, all of which require a lot of energy; in addition, each of these processes creates a lot of internal heat and moisture, which has to be drawn out of the kitchen with sufficiently dimensioned ventilation systems due to which a large part of the energy used in commercial kitchens is devoted to ventilation. | ||
+ | [[.: | ||
- | {{ : | + | ---- |
- | [[Commercial kitchens and cafeterias]] | + | [{{ : |
+ | ===== Passive House retail / supermarkets ===== | ||
- | ---- | + | There are several examples of retail buildings to the Passive House standard. The most popular retail typology are supermarkets, |
- | ===== Passive House retail ===== | + | Watch the [[: |
- | [{{ : | + | Additional relevant background information on selected topic relevant for retail buildings |
- | //These and more articles | + | |
- | [[planning: | + | * [[.: |
- | + | * [[:phi_publications: | |
- | + | ||
- | === Nr.40 Passive House retail establishments | + | |
- | * [[phi_publications: | + | |
- | \\ | + | |
---- | ---- | ||
Line 91: | Line 85: | ||
Passive House laboratories are a very specific form of non-residential building. Moreover, the term describes a very heterogeneous mixture of usages, ranging from light-duty, slightly extended office use to heavily ventilated buildings with very strong internal heat sources and hazardous substances in the extracted air. | Passive House laboratories are a very specific form of non-residential building. Moreover, the term describes a very heterogeneous mixture of usages, ranging from light-duty, slightly extended office use to heavily ventilated buildings with very strong internal heat sources and hazardous substances in the extracted air. | ||
- | **Read more about [[planning: | + | Read more about [[.: |
+ | ---- | ||
- | \\ | + | ===== Building automation ===== |
+ | |||
+ | The achievable level of energy efficiency of buildings is mainly determined by the building design and selection of the quality of building components during the planning and execution phases. Consumption later on is also influenced by actual building use. In non-residential buildings, control parameters have an influence to a relevant degree (e.g. operating times, supply temperatures, | ||
+ | |||
+ | Identifying malfunctions as well as unsuitable operating parameters based on observations is the task of technical monitoring, which is recommended for systematic commissioning and optimising operations. | ||
+ | |||
+ | Last but not least, the perspective of the users should always be considered right from the planning stage, which explicitly includes the technical operations personnel. | ||
+ | |||
+ | [[.: | ||
---- | ---- | ||
+ | |||
===== Retrofitting non-residential buildings to the Passive House / EnerPHit-standard ===== | ===== Retrofitting non-residential buildings to the Passive House / EnerPHit-standard ===== | ||
- | **Factors that influence the energy balance and affordability of non-residential EnerPHit-projects** | + | **Factors that influence the energy balance and affordability of non-residential EnerPHit-projects** |
- | Does it make sense to retrofit non-residential buildings with Passive House components if the buildings have a lot of internal heat sources? \\ | + | Does it make sense to retrofit non-residential buildings with Passive House components if the buildings have a lot of internal heat sources? \\ [[:basics: |
- | [[basics: | + | |
- | \\ | + | |
=== Nr.48 Using Passive House technology for retrofitting non-residential buildings === | === Nr.48 Using Passive House technology for retrofitting non-residential buildings === | ||
- | | + | |
- | * [[phi_publications: | + | |
- | \\ \\ | + | * [[:phi_publications: |
---- | ---- | ||
Line 115: | Line 117: | ||
====== See also ====== | ====== See also ====== | ||
- | [[phi_publications: | + | [[:phi_publications: |
+ | |||
+ | [[: | ||
- | [[phi_publications: | + | [[:phi_publications: |
- | [[phi_publications: | ||
planning/non-residential_passive_house_buildings.1654002251.txt.gz · Last modified: 2022/05/31 15:04 by yaling.hsiao@passiv.de