Fulltext results:
- Passive House schools – How to go about it @planning:non-residential_passive_house_buildings:passive_house_schools
- ndations are not meant to be requirements – it is possible to deviate from them, but then compensating measu... implementation]] should be strived for as much as possible; this is generally easily achievable except at th... oint of load bearing internal walls. If it is not possible to design details in a completely thermal-bridge-... ner, thermal bridges should be reduced as much as possible and the corresponding losses should be taken into
- Passive House Schools - Boundary Conditions @planning:non-residential_passive_house_buildings:passive_house_schools
- this raises a number of questions (hygiene of any possible moisture recovery or supply air humidification, m... logy used is robust and simple and, if necessary, possible to operate manually (no “technological Christmas ... es the usual heating using supply air, it is also possible to heat up the rooms to a comfortable level durin... n to the radiation temperature asymmetry) is only possible if **the building's envelope surfaces have a high
- Aspects of efficient ventilation in hospitals @planning:non-residential_passive_house_buildings:ph_hospitals
- at switches off outside of business hours is even possible in operating rooms (in accordance with ÖNORM 6020... sses by a third. Pressure losses < 75 Pa are even possible for airborne-particle filters with a depth of > 2... sses, make sure the duct network is as compact as possible, especially where large amounts of air flow. When... pment cabinets, on the one hand, and the shortest possible ducts for outdoor air and exhaust air, on the oth
- Baseline study - implementing the Passive House concept in hospitals @planning:non-residential_passive_house_buildings:ph_hospitals
- nd hospital management as early in the process as possible. \\ In rooms where medical care is provided, the... ensive energy savings will probably only truly be possible if such products also have energy labels. It is u... nd cooling. \\ All standard supply solutions are possible. Cogeneration is an interesting solution because ... t water network should therefore be as compact as possible and insulated above and beyond what's required by
- Introduction: Retail stores as Passive Houses
- ailers. These stores are realised with the lowest possible construction costs and in the form of halls witho... ould be better to deliberately induce the maximum possible transmission losses in order to reduce the coolin
- Energy efficiency in cafeterias and commercial kitchens @planning:non-residential_passive_house_buildings:cafeterias_and_commercial_kitchens
- ers and managers) start participating as early as possible and that actual requirements be specified. Only