Fulltext results:
- Types of ventilation @planning:building_services:ventilation:basics
- ed and adequate exchange of air in winter is only possible by means of comfort ventilation – this also appl... ve the indoor air quality ourselves and it is not possible for us to estimate the amount of fresh air actual... air pollution should be limited at the source if possible (as Max von Pettenkofer once put it: "One can't a... being made to keep indoor air pollution as low as possible.))\\ \\ ==== Why opening the windows twice a day
- Passive House schools – How to go about it @planning:non-residential_passive_house_buildings:passive_house_schools
- ndations are not meant to be requirements – it is possible to deviate from them, but then compensating measu... implementation]] should be strived for as much as possible; this is generally easily achievable except at th... oint of load bearing internal walls. If it is not possible to design details in a completely thermal-bridge-... ner, thermal bridges should be reduced as much as possible and the corresponding losses should be taken into
- Insulation vs. thermal mass @planning:thermal_protection:thermal_protection_works
- s what defines serious science and makes progress possible in the first place and enabled the present level ... k of "absolute truth", but it does allow the best possible description of the facts possible today. Furthermore, these statements can be checked by everyone, even re... easurement)|the following example]]. Today it is possible to apply this differential equation with the help
- Airtightness and airtightness measurement @planning:refurbishment_with_passive_house_components:thermal_envelope
- the volume to be tested in large buildings it is possible to divide the building into several zones and tes... ically feasible. In most buidlings it will not be possible to achieve a perfect airtight separation of the z... 95] ]]): \\ \\ ^1. The “pencil rule”: it must be possible to trace the airtight layer of the envelope in th... ction details should be as simple to carry out as possible * preferably **large uniform** areas with a si
- Air volumes @planning:building_services:ventilation:basics
- t energy-relevant or practical! Of course, it is possible to transfer even more air – and in theory, in the... "Normal" setting in spite of the fact that it is possible for occupants to change the setting. * Even in... nd it is too expensive. Of course, it is entirely possible that with clever ideas and new technologies, much... with equal fan efficiency areas" with the highest possible efficiency for average continuous operation).
- Windows in a step-by-step retrofit @planning:refurbishment_with_passive_house_components
- uld always be retrofitted simultaneously whenever possible. Where it is not possible, the following tips from the EuroPHit project are helpful. ===== 2. First window... olutions that are as affordable and functional as possible over the window’s lifecycle with consideration of... cant thermal bridge effect. As much insulation as possible should be used between the roller shutter box and
- Compact HVAC systems @planning:building_services
- oads of a Passive House building. This makes it possible to develop convincingly simple building services ... for use in warmer climates. Various solutions are possible for generating heat. Each of which are described ... space is needed to store this – it would even be possible to get the small amount of fuel along with the we... s that even with a low output, heat generation is possible with gas. In spite of that, it took a long time b
- Internal heat gains in relation to living area @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- wn occupancy, equipment etc.) is naturally always possible. \\ \\ ==== 1 Occupancy in relation to living are... ased on [NRW 2011]|\\ From this data, it is thus possible to derive the individual amounts according to the... e PHPP. This is of significance because it is not possible to count the entire electricity consumption as in... lamps (fluorescent lamps as well as LED lamps are possible; older measurements still include a large proport
- Passive House Schools - Boundary Conditions @planning:non-residential_passive_house_buildings:passive_house_schools
- this raises a number of questions (hygiene of any possible moisture recovery or supply air humidification, m... logy used is robust and simple and, if necessary, possible to operate manually (no “technological Christmas ... es the usual heating using supply air, it is also possible to heat up the rooms to a comfortable level durin... n to the radiation temperature asymmetry) is only possible if **the building's envelope surfaces have a high
- Dynamic simulation of a building's thermal performance @planning:calculating_energy_efficiency
- including all electric appliances. This makes it possible to simulate the internal heat gains. General assu... Darmstadt Kranichstein; see fif. 3). It had been possible to predict the energy consumptions, as well as to... pletely superfluous (validation of models is only possible via measurements) - nor is it practical and sensi... carefully observed during measurements - this is possible, but often increases the effort significantly bey
- Energy balances - Background @planning:calculating_energy_efficiency
- solar energy can be estimated well enough, it is possible to calculate the remaining heat supply required (... s the active cooling sheet in PHPP.\\ It is also possible, to give an assessment of the thermal comfort if ... with caution – and in case of doubt, the largest possible reference area should be assumed for assessment. ... annual energy consumption. There is no confusion possible here at least for the reference size (as there is
- Aspects of efficient ventilation in hospitals @planning:non-residential_passive_house_buildings:ph_hospitals
- at switches off outside of business hours is even possible in operating rooms (in accordance with ÖNORM 6020... sses by a third. Pressure losses < 75 Pa are even possible for airborne-particle filters with a depth of > 2... sses, make sure the duct network is as compact as possible, especially where large amounts of air flow. When... pment cabinets, on the one hand, and the shortest possible ducts for outdoor air and exhaust air, on the oth
- Baseline study - implementing the Passive House concept in hospitals @planning:non-residential_passive_house_buildings:ph_hospitals
- nd hospital management as early in the process as possible. \\ In rooms where medical care is provided, the... ensive energy savings will probably only truly be possible if such products also have energy labels. It is u... nd cooling. \\ All standard supply solutions are possible. Cogeneration is an interesting solution because ... t water network should therefore be as compact as possible and insulated above and beyond what's required by
- Overall retrofit plan for step-by-step retrofits to EnerPHit Standard @planning:refurbishment_with_passive_house_components
- uilding as a Passive House or EnerPHit project is possible. Unlike for certifications of completed buildings... for each of the retrofit steps. By doing so it is possible to provide a comprehensive document to building o... for each of the retrofit steps. By doing so it is possible to provide a comprehensive document to building o
- Refurbishment with Passive House components - introduction @planning:refurbishment_with_passive_house_components
- improvement“ with justifiable effort: while it is possible to carry out the better measures today at low dif... shows how important it is to achieve the highest possible level of energy efficiency that is economically viable. Only then will it be possible to reduce energy consumption to a level which is
- Improving thermal bridges and airtightness in existing buildings @planning:refurbishment_with_passive_house_components:thermal_envelope
- Insulation works – Evidence no.1 "Measurements at a highly insulated wall" @planning:thermal_protection:thermal_protection_works
- Prospects for the modernisation of existing buildings using highly efficient components @planning:refurbishment_with_passive_house_components
- Step-by-step Retrofits towards EnerPHit Standard in social housing in Spain @planning:refurbishment_with_passive_house_components
- Checklist: Test reports of airtightness measurements @planning:airtight_construction:general_principles
- PHPP - validated and proven in practice @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- Comparison of in-situ measurements and hygrothermal simulations of four different interior insulation systems @planning:thermal_protection:thermal_protection_works:comparison_of_in_situ_measurements_and_hygrothermal_simulations_of_four_different_interior_insulation_systems
- Building Integrated Photovoltaics (BIPV) in Step by Step Retrofitting Projects @planning:refurbishment_with_passive_house_components
- “designPH” plugin for Trimble Sketchup @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- Variant calculations and economic assessment with PHPP 9 @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- Energy efficiency in cafeterias and commercial kitchens @planning:non-residential_passive_house_buildings:cafeterias_and_commercial_kitchens
- Influence of retrofitting on daylighting @planning:refurbishment_with_passive_house_components:mechanical_systems
- Experience with drain water heat recovery @planning:building_services:heating_and_dhw:experience_with_drain_water_heat_recovery