Fulltext results:
- Thermal comfort parameters @basics:building_physics_-_basics:thermal_comfort
- ned by Fanger’s equation, documented in ISO 7730 (see also [[phi_publications:pb_25:comfort_criteria_ac... ternal building components is under 0.85 W/(m²K). See Fig. 2 in the left column. * The percieved... bout well insulated buildings. [ 4 ] \\ \\ ===== See also ===== [[Planning:thermal_protection:window
- Heating load in Passive Houses
- is around 10 W/m² - irrespective of the climate (see box). \\ The specific values for heating loads a... cialists, thus facilitating their work. \\ ===== See also ===== [[basics:building_physics_-_basics:he
- What defines thermal bridge free design?
- by a horizontal blue line. However, one can also see that substantial thermal bridge losses can result... sicherung Tevesstraße Frankfurt am Main]] ===== See also ===== [[basics:building_physics_-_basics:hea
- Adaptive versus Heat Balance Comfort Models @basics:building_physics_-_basics:thermal_comfort
- buildings the heat balance models are suggested (see figure below). It appears quite strange that the ... plied Science Publishers, London 1980 \\ ====== See also ====== [[planning:calculating_energy_efficie
- Local thermal comfort @basics:building_physics_-_basics:thermal_comfort
- l building component is less than 0.85 W/(m²K)**. See. the illustration on the [[basics:building_physic... fort#Literature|[Hermelink 2004] ]]).\\ \\ ===== See also ===== [[Planning:thermal_protection:windows
- Examples of thermal bridge calculations @basics:building_physics_-_basics:thermal_bridges:tbcalculation
- Heated basement @basics:building_physics_-_basics:thermal_bridges:tbcalculation:examples
- install insulation under the foundation as well (see AkKP 35). Regardless of that, the question that a... hree-dimensional transient calculations.// ===== See also ===== * [[basics:building_physics_-_basic
- Interior walls on floor slabs @basics:building_physics_-_basics:thermal_bridges:tbcalculation:examples
- effect" of the ground is not taken into account (see Figure 1). As a matter of fact the thermal bridge... ith the increasing distance to the edge.// ===== See also ===== * [[basics:building_physics_-_basics
- Unheated basement @basics:building_physics_-_basics:thermal_bridges:tbcalculation:examples
- face between the basement and the interior space (see figure above). This is expressed by the following... $f_{Rsi}$* factor can also be given here. ===== See also ===== * [[basics:building_physics_-_basic
- Special features and characteristics of components in contact with the ground @basics:building_physics_-_basics:thermal_bridges:tbcalculation:ground_contact
- ner are therefore also used as harmonic Ψ-values (see the Ground worksheet in the [[planning:calculatin... as-erdreich-45/|Link to PHI publications]] ===== See also ===== * [[basics:building_physics_-_basics
- Recommended procedure for calculating thermal bridges of components in contact with the ground @basics:building_physics_-_basics:thermal_bridges:tbcalculation:ground_contact
- dditional boundary condition for the temperature (see DIN 4108 Supplementray Sheet 2) All methods cons... at least five or six times the floor slab length (see illustration). * The external dimensional refe
- Thermal bridge calculation @basics:building_physics_-_basics:thermal_bridges
- s:building_physics_-_basics:thermal_bridges:tbcalculation:examples:unheatedb]] ==== See Also ====
- Definition and effects of thermal bridges @basics:building_physics_-_basics:thermal_bridges
- for Passive House Component certification]] ===== See also===== * [[basics:building_physics_-_basics
- Thermal Bridges Catalogue @basics:building_physics_-_basics:thermal_bridges
- pen:sinfonia_eu_phi.png?nolink&300}} ---- ===== See also ===== Click [[:planning:guides_and_aids|her