Fulltext results:
- The Passive House in summer
- de of the\\ Darmstadt-Kranichstein Passive House (see picture below)**//||\\ \\ \\ {{:picopen:passivhau... the temperature processes in the Passive House. (See [[Planning:calculating energy efficiency:Dynamic ... ot period in the room "South Top Floor". One can see that all indoor temperatures in this time period ... to 0.475 h<sup>-1</sup>), the reading is 10.77% (see reference case). If the permanent air exchange is
- The Passive House – historical review
- a research project concerning "passive houses". See [[Basics:The Passive House - historical review#Li... s set aside in favour of the "low-energy house". See [[Basics:The Passive House - historical review#Li... ive versus Active Measures in Europe & America]]. See also [[Basics:The Passive House - historical revi... low-energy houses and Passive Houses in Europe. See [[Basics:The Passive House - historical review#Li
- Economic feasibility of Passive House design @basics:affordability
- and the relevant investment costs, respectively – see figure 1 for several variants of renovation a bui... ufacturer and installer, plumber, electricians,…. see, figure 2. \\ Construction: Cellar with concrete... round: lightweight wooden prefabricated elements, see table in figure 2. Invoiced construction costs fo... air change. For all other configuration features see in table in figure 2. \\ The costs of all compone
- Are Passive Houses cost-effective? @basics:affordability:investing_in_energy_efficiency
- lightly thicker than it was before (about 25 mm) (see __**Fig. 2**__).//{ Remark from 2015: Because of ... concept for air distribution has been redesigned (see __**Fig. 3 and 4**__).\\ \\ |{{ :picopen:passivha... , such\\ windows have many additional advantages, see this page:\\ [[Planning:Thermal protection:Window... can now be lower.\\ Notice concerning methodology see:// ((**Notice concerning methodology:**\\ \\ Here
- Efficiency vs. Efficiency Factor
- ses is just as effective for cooling performance (see __**//Fig 1//**__). * By using heat recovery, ... uum-insulated cooling space. * Transportation (see __**//Fig 2//**__): non-equilibrium state, " move... ctionless vehicle on a **brachistochrone curve**; see Fig 2 \\ \\ |{{ :basics:brachistochrone_fast_lan... eversible. //**||\\ \\ //For those, who want to see the proof - it's at the end of this page//\\ \\
- What is a Passive House?
- ====== What is a Passive House? ====== Want to see a video first? Click the video-frame: **{{ youtube>x... d the level of comfort is considerably increased (see [[basics:building_physics_-_basics:thermal_comfor... nds-on experience of Passive Houses – You have to see one to believe it ==== The International Passive ... ere to view [[:examples|Passive House examples]]. See also: [[http://www.passivehousedatabase.eu/search
- Greenhouse effect and climate protection @basics:energy_and_ecology
- for example, melting glaciers.\\ \\ |{{ :picopen:see_eis_wf.gif }}|//**The northern polar region (imag... y keeps increasing, significantly and measurably (see the following illustration), due to the continued... sured in the Atmosphere's CO<sub>2</sub> contend (see the Graph following) is indeed mainly caused by t... www.skepticalscience.com/anthrocarbon-brief.html| See: antgropogenic CO2?]] - Fossil fuels do not conta
- Zero-energy and zero heating energy houses @basics:energy_and_ecology
- y-efficient household appliances are used.\\ \\ //See also [[Basics:Energy and ecology:Primary energy –... ://www.passiv.de/07_eng/index_e.html|certificate (see Certification -> Certified products)]] by the Pas... gy is fed into the network than is taken from it. See also this technical paper on [[Basics:Energy and ... ewable energy carriers there will be.\\ \\ ===== See also ===== [[basics:energy_and_ecology:primary_e
- Passive House – the next decade @basics:passive_house_-_assuring_a_sustainable_energy_supply
- lternative to today's mostly fossil-based supply (see [[basics:passive_house_-_assuring_a_sustainable_e... les per year), even if costs drop significantly (see [[basics:passive_house_-_assuring_a_sustainable_e... f space required for renewable energy generators (see Section [[basics:passive_house_-_assuring_a_susta... xt_decade#references|[Schnieders et al., 2012]]], see also [[basics:passive_house_-_assuring_a_sustaina
- Superior thermal protection is affordable @basics:affordability:investing_in_energy_efficiency
- ptimum measures in terms of cost-effectiveness** (see __**Table**__). In this respect, the recommendati... energy price of 4.5 cents/kWh for the year 2005 (see __**Table**__). By the end of 2005 and beginning ... as the average future energy price in the study (see [[Basics:Affordability:Investing in energy effici... ementation was strongly recommended in the study (see [[Basics:Affordability:Investing in energy effici
- Passive House – the next decade | Determining application-specific PER factors @basics:passive_house_-_assuring_a_sustainable_energy_supply:passive_house_the_next_decade
- arly ideal solution for power supply for heating (see Figure 9), although a PV share of 10 to 50 percen... sons, the biogas share is considered separately – see next section). This renewable primary energy fact... e is a mix of renewable and nonrenewable sources (see [[basics:passive_house_-_assuring_a_sustainable_e... e for different cogeneration rates. It is easy to see that the share of cogeneration heat is absolutely
- Internal heat capacity
- e thermal insulation will still be of importance (see [[Basics:Internal heat capacity#Literature|[AkkP-... herefore largely constant temperatures in summer (see [[Basics:Internal heat capacity#Literature|[Schni... openable windows in each room of a Passive House (see [[Operation:Operation and Experience:User behavio
- Philips Experimental House Research 1974ff: Passive versus Active Measures in Europe & America @basics:the_passive_house_-_historical_review
- Parameter Studies**| \\ The experimental house (see Hörster et al. 1980, Fig. 1) was an upgraded off-... tudies including the US & Europe where performed (see e.g. Bruno & Steinmüller 1977, Bruno & Hörster 19... pact of window parameters under various climates (see Fig. 3, Steinmüller 1979 and 1982). It turned out
- Cost-effectiveness analysis @basics:affordability:investing_in_energy_efficiency
- ng term, there will be an overall capacity limit, see "peak oil".//\\ \\ |{{:picopen:energiepreis2006_n... lusions for the energy price level in the future (see Fig. 1) ==== Thus we venture that there will be ... he International Passive House Conference. ===== See also ===== [[basics:affordability:investing_in_e
- Economy and financing of efficiency: new buildings, renovation and step by step retrofit @basics:affordability:investing_in_energy_efficiency
- e expected rates of return are inadequately high (see next chapter)\\ * Future energy prices and pri... aluated on the basis of correct life cycle costs (see ). For such renovations, PHI has established the ... e information contained therein.//| \\ \\ ====== See also ====== [[basics:affordability|Overview]] of
- Life Cycle energy balances, Embodied energy and the Passive House Standard @basics:energy_and_ecology
- Efficiency of household appliances and their impact on the primary energy demand of residential buildings @basics:passive_house_-_assuring_a_sustainable_energy_supply
- Renewable primary energy demand in residential buildings with high energy intensity @basics:passive_house_-_assuring_a_sustainable_energy_supply
- Introduction - Passive House buildings in different climates @basics:passive_houses_in_different_climates
- Examples of thermal bridge calculations @basics:building_physics_-_basics:thermal_bridges:tbcalculation
- Interior walls on floor slabs @basics:building_physics_-_basics:thermal_bridges:tbcalculation:examples
- Special features and characteristics of components in contact with the ground @basics:building_physics_-_basics:thermal_bridges:tbcalculation:ground_contact
- Recommended procedure for calculating thermal bridges of components in contact with the ground @basics:building_physics_-_basics:thermal_bridges:tbcalculation:ground_contact