Fulltext results:
- Types of ventilation @planning:building_services:ventilation:basics
- h air. Opening windows twice a day is not enough (see [[[planning:building services:Ventilation:Basics:... aks is not adequate in the heating period at all (see also [[Planning:Airtight construction]]): \\ *... hour is insufficient for good health and comfort (see following illustration).\\ \\ ==== Why is an ade... d humidity can be seen clearly. * One can also see that each time the window is opened for air excha
- Compact HVAC systems
- tructions and in energy efficient refurbishments! See also the article about [[planning:building servic... hygiene can be provided for the supply air rooms (see heat capacity of fresh air). In a Passive House, ... hich facilitated the development of such systems. See this article for more details about the energy ba... vailable on the market (mainly for cost reasons). See also this article for [[basics:passive_houses_in_
- Air volumes @planning:building_services:ventilation:basics
- eased effort for maintenance, hygiene and energy; see section about ventilation/humidity).\\ \\ ==== A... at -5°/90% only about 3 g per cubic metre of air, see following illustration).\\ \\ |{{:picopen:vapour-... about physiological impairments at low indoor air see {{:picopen:low_humidity.pdf|here}}. In this case,... which must however be cleaned regularly. ===== See also ===== [[planning:building_services:ventilat
- The ventilation system – there is no alternative @planning:building_services:ventilation
- revention of areas with local thermal discomfort (see also “Thermal Comfort in the Passive House”), *... CO2 concentration would have reached 0.8 vol. % (see table and figure below).\\ \\ Table: increase in ... ouse criteria and build a Passive House. ===== See also ===== [[planning:building_services:ventilat
- Ventilation
- /en/components/| certified ventilation units ]]to see all the high-efficient components. Additional ar... tals]] ===== ===== ===== ===== ---- ===== See also ===== Read more about **[[https://passipedi
- Experience with drain water heat recovery @planning:building_services:heating_and_dhw:experience_with_drain_water_heat_recovery
- y determining expected savings in specific cases (see AkkP49).\\ The following points are particularly... g Group on Affordable Passive Houses\\ \\ ====== See also ====== [[planning:building_services:heating
- Supplying Passive Houses with sustainable energy @planning:building_services:heating_and_dhw
- llage as a whole. \\ \\ With this example, we can see that the "zero carbon" approach is much too short
- Comparison of energy performance of ventilation systems using passive vs. active heat recovery @planning:building_services:ventilation
- vide heating, cooling, dehumidification and DHW - see this article on [[..:compact_hvac_systems|compact
- Differentiation between Vv and Vn50 values @planning:building_services:ventilation
- ered room height. For further reference, please see the current PHPP manual (PHPP 9 manual: section 2
- Passive House - 6 reasons why you still need opening windows @planning:building_services:ventilation
- ve effect is a slight increase in heating energy (see [[operation:operation_and_experience:user_behavio