Fulltext results:
- Types of ventilation @planning:building_services:ventilation:basics
- h air. Opening windows twice a day is not enough (see [[[planning:building services:Ventilation:Basics:... aks is not adequate in the heating period at all (see also [[Planning:Airtight construction]]): \\ *... hour is insufficient for good health and comfort (see following illustration).\\ \\ ==== Why is an ade... d humidity can be seen clearly. * One can also see that each time the window is opened for air excha
- Energy balances - Background @planning:calculating_energy_efficiency
- . constant, inside the building being considered (see [[Planning:calculating energy efficiency:Energy b... can be solved by using **simulation programmes** (see [[Planning:calculating energy efficiency:Dynamic ... hese in the **"Passive House Planning Package"** (see [[Planning:calculating energy efficiency:PHPP - t... ch as has been shown by many systematic analyses (see [[planning:thermal_protection:thermal_protection_
- Compact HVAC systems @planning:building_services
- tructions and in energy efficient refurbishments! See also the article about [[planning:building servic... hygiene can be provided for the supply air rooms (see heat capacity of fresh air). In a Passive House, ... hich facilitated the development of such systems. See this article for more details about the energy ba... vailable on the market (mainly for cost reasons). See also this article for [[basics:passive_houses_in_
- PHPP – Passive House Planning Package @planning:calculating_energy_efficiency
- ive cooling: frequency of overheating events [%] (see [[:a_simplified_method_for_determining_thermal_co... after changing an entry the user can immediately see the effect on the energy balance of the building.... |//**On this clearly arranged flow chart you can see how the PHPP works** \\ \\ Illustration: Sarah L... , Darmstadt 1998// \\ (only available in German); see e.g. [[:phi_publications:pb_13:recommendations_fo
- Economic analysis for the retrofit of a detached single family house to the EnerPHit standard @planning:refurbishment_with_passive_house_components
- , along with a wood log stove in the living room. See photos and construction details on http://europhi... of 5 to 15% of the low-energy reference scenario (see study [1] in France, and the feasibility study on... ve have been derived from a French cost database. See cost table below: \\ [{{ :picopen:t._annual_costs... er total annual cost than the low-energy variant (see Figure 2) at €6500/a. The actualised payback peri
- Passive House schools – How to go about it @planning:non-residential_passive_house_buildings:passive_house_schools
- F7 for external air) and to keep this filter dry (see also [[planning:non-residential_passive_house_bui... :air_quality_in_schools|Air Quality in Schools]]; see Protocol Volume section by R. Pfluger and the Pro... e_schools_requirements#Literature|[PHPP 2007] ]] (see [[planning:non-residential_passive_house_building... 2007**, Passive House Institute, Darmstadt 2007), see page [[Planning:calculating energy efficiency:PHP
- Outdoor thermography @planning:thermal_protection:thermal_protection_works
- ven through measurements and have been published (see [[planning:refurbishment_with_passive_house_compo... ackages of\\ insulation panels attached to them (see regular picture).\\ \\ \\ **//|//**Regular pictur... is also lower – which may cause severe problems (see [[planning:thermal_protection:thermal_protection_... long as the window is no opened for a long time - see for more information the following Passipedia art
- Calculating energy efficiency
- h a model can provide accurate results ([AkkP 5] (see Figure 1), but this requires a lot of effort and ... plane)**\\ \\ Simulation programme used: DYNBIL; see [[planning:calculating energy efficiency:Dynamic ... hich is suitable for practical planning purposes (see Figure 2). \\ \\ |{{ :picopen: comparison_method_... ive House Institute, Darmstadt 2007 \\ \\ ====== See also ====== **[[planning:calculating_energy_effi
- Commercial kitchens and cafeterias
- n]]** {{:picopen:members_only.png?nolink&20|}} **See also:** [[phi_publications:pb_41:planning_tools_... s]]** {{:picopen:members_only.png?nolink&20|}} **See also:** [[phi_publications:pb44_planning_aspects... "]] {{:picopen:members_only.png?nolink&20|}}** **See also:** [[phi_publications:nr.40_food_refrigerat... energy offices conference)**, 2009.| ---- =====See also===== [[planning:non-residential_passive_hou
- Introduction: Retail stores as Passive Houses @planning:non-residential_passive_house_buildings
- g, despite the high loads caused by the lighting (see below). At the same time, the temperatures in fro... er subordinate role in retail stores up till now (see e.g. Figure 4). Not only is it disregarded but so... rly with reference to the efficiency of lighting (see the article "Daylight and artificial lighting" by... taken into account during planning. \\ \\ ====== See also ====== [[planning:non-residential_passive_h
- Thermal insulation @planning:thermal_protection
- sulation and not heat storage which is important (see [[planning:thermal_protection:thermal_protection_... ve thermal comfort and prevent structural damage (see [[Planning:Thermal protection:Integrated thermal ... input stated. This is proven by thermal images (see below) which reveal clearly elevated temperatures... mum when designing a Passive House. ---- ===== See also ===== [[planning:thermal_protection:don_t_s
- Why build an airtight house? – Leakage problems @planning:airtight_construction:general_principles
- nly be prevented by airtightness of the envelope (see illustration). Building damage is mostly due to ... e very good values can be achieved regularly. (To see these figures as "very tough" is just a beginners... s seem to be especially sensitive to cold drafts (see ISO 7730) - and there are two important causes fo... how to deign and to build really airtight. ===== See also ===== [[planning:airtight_construction:gene
- Airtightness and airtightness measurement @planning:refurbishment_with_passive_house_components:thermal_envelope
- . This high requirement is frequently fulfilled (see [[.:airtightness:special_features_in_modernisatio... -airtight – with a constant n<sub>50</sub>-value (see //**Figure 2 with Table 1**// ). It is therefore ... n.png?500 }}| |//**Figure 3: The possibilities (see above (I) to (III)) for a permanently airtight \\... chedule * Monitoring of implementation ====== See also ====== [[planning:refurbishment_with_passiv
- Thermal protection in retrofits @planning:thermal_protection:thermal_protection_works
- the high heat losses through external walls are (see diagram below). It is particularly important, no... -insulated, mainly from the health point of view (see paragraph above [[planning:thermal_protection:the... Conclusion ===== Based on these example, we can see that excellent thermal protection is of consider... the useable energy savings potential. \\ ===== See also ===== [[Planning:Thermal protection:Thermal
- Insulation vs. thermal mass @planning:thermal_protection:thermal_protection_works
- Oh, if only this was finally generally accepted! (see Max Born: My Life and My Views: A Nobel Prize Win... already averages out over a period of a few days (see the explanation in [[planning:thermal_protection:... ults are in good agreement with measured results (see the page about [[Planning:calculating energy effi... ut through their work and actions//".\\ \\ ===== See also ===== [[planning:thermal_protection:don_t_s
- Refurbishment with Passive House components - introduction @planning:refurbishment_with_passive_house_components
- Passive House Schools - Boundary Conditions @planning:non-residential_passive_house_buildings:passive_house_schools
- Insulation works – Evidence no.1 "Measurements at a highly insulated wall" @planning:thermal_protection:thermal_protection_works
- Energy use for heating in a well insulated new building @planning:thermal_protection:thermal_protection_works
- Internal heat gains in relation to living area @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- Energy efficiency in cafeterias and commercial kitchens @planning:non-residential_passive_house_buildings:cafeterias_and_commercial_kitchens
- Ventilation in commercial kitchens @planning:non-residential_passive_house_buildings:cafeterias_and_commercial_kitchens
- Aspects of efficient ventilation in hospitals @planning:non-residential_passive_house_buildings:ph_hospitals
- Experience with drain water heat recovery @planning:building_services:heating_and_dhw:experience_with_drain_water_heat_recovery
- PHI window certification: previous success and new climate zones @planning:thermal_protection:windows:window_certification
- Component Award 2016: Affordable ventilation solutions for retrofits @planning:refurbishment_with_passive_house_components
- Building Integrated Photovoltaics (BIPV) in Step by Step Retrofitting Projects @planning:refurbishment_with_passive_house_components
- Step-by-step Retrofits towards EnerPHit Standard in social housing in Spain @planning:refurbishment_with_passive_house_components
- Checklist: Test reports of airtightness measurements @planning:airtight_construction:general_principles
- Comparison of energy performance of ventilation systems using passive vs. active heat recovery @planning:building_services:ventilation
- Passive House - 6 reasons why you still need opening windows @planning:building_services:ventilation
- PHPP calculations in hot and humid climates @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- “designPH” plugin for Trimble Sketchup @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- PHPP - validated and proven in practice @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- The overall heat transfer coefficient or U-value @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- Variant calculations and economic assessment with PHPP 9 @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- Baseline study - implementing the Passive House concept in hospitals @planning:non-residential_passive_house_buildings:ph_hospitals
- Influence of retrofitting on daylighting @planning:refurbishment_with_passive_house_components:mechanical_systems
- Floor Replacement: Svartbäcksvägen @planning:refurbishment_with_passive_house_components:thermal_envelope