• skip to content

User Tools

  • Log In

Site Tools

  • Recent Changes
  • Media Manager
  • Sitemap
You are here: Cloud Plugin » standard

standard

Search

You can find the results of your search below.

Exact match
  • Exact match
  • Starts with
  • Ends with
  • Contains
@basics:building_physics_-_basics
  • Any namespace
  • basics:building_physics_-_basics:thermal_bridges (11)
  • basics:building_physics_-_basics:thermal_comfort (3)
Any time
  • Any time
  • Past week
  • Past month
  • Past year
Sort by hits
  • Sort by hits
  • Sort by last modified

Fulltext results:

Thermal bridge calculation @basics:building_physics_-_basics:thermal_bridges
12 Hits, Last modified: 11 months ago
Heating load in Passive Houses
5 Hits, Last modified: 6 years ago
ld measurements: by building to the Passive House Standard, it is actually possible to achieve energy saving... to the DIN 1946 – health criterion). At 21°C and standard pressure, air has a heat capacity of 0.33 Wh/(m<s... nimal requirements. If occupants requiring a high standard of comfort are present, internal heat gains exist... e design output in accordance with the [DIN 4701] standard, even at extremely low outdoor temperatures. This
What defines thermal bridge free design?
3 Hits, Last modified: 3 years ago
the external surfaces and regular U-values of the standard building elements alone. Regularly occurring thermal bridges in standard building components must already be taken into ac... efore be decisive for achieving the Passive House standard in the first place.\\ \\ [{{:picopen:thermo_ext_
Thermal Bridges @basics:building_physics_-_basics:thermal_bridges
3 Hits, Last modified: 16 months ago
Definition and effects of thermal bridges @basics:building_physics_-_basics:thermal_bridges
3 Hits, Last modified: 3 years ago
rate and lower surface temperatures than adjacent standard building components. They occur particularly at t... oints, edges, transitions and penetrations of the standard building components. They are depicted by the lin... efore be decisive for achieving the Passive House Standard in a construction project. ==== Effect on the b
Examples of thermal bridge calculations @basics:building_physics_-_basics:thermal_bridges:tbcalculation
3 Hits, Last modified: 6 years ago
Heated basement @basics:building_physics_-_basics:thermal_bridges:tbcalculation:examples
3 Hits, Last modified: 3 years ago
Interior walls on floor slabs @basics:building_physics_-_basics:thermal_bridges:tbcalculation:examples
3 Hits, Last modified: 4 years ago
Unheated basement @basics:building_physics_-_basics:thermal_bridges:tbcalculation:examples
3 Hits, Last modified: 3 years ago
Special features and characteristics of components in contact with the ground @basics:building_physics_-_basics:thermal_bridges:tbcalculation:ground_contact
3 Hits, Last modified: 3 years ago
Recommended procedure for calculating thermal bridges of components in contact with the ground @basics:building_physics_-_basics:thermal_bridges:tbcalculation:ground_contact
3 Hits, Last modified: 6 years ago
Thermal comfort parameters @basics:building_physics_-_basics:thermal_comfort
2 Hits, Last modified: 5 years ago
mfort equation]]). Furthermore, according to this standard it is essential that * the sultriness limit ... ing that by the requirements of the passive house standard all comfort criteria are automatically optimally
Thermal Bridges Catalogue @basics:building_physics_-_basics:thermal_bridges
1 Hits, Last modified: 10 months ago
not possible (e.g. modernisation to the EnerPHit Standard), this thermal bridge catalogue can support the d
Adaptive versus Heat Balance Comfort Models @basics:building_physics_-_basics:thermal_comfort
1 Hits, Last modified: 6 years ago
y experiments. They resulted in the international standard ISO 7730 which allows for the calculation of the
Local thermal comfort @basics:building_physics_-_basics:thermal_comfort
1 Hits, Last modified: 6 years ago
um way with the requirements of the Passive House Standard - Improved thermal insulation simultaneously impr
Exterior wall on floor slab @basics:building_physics_-_basics:thermal_bridges:tbcalculation:examples
1 Hits, Last modified: 3 years ago

Page Tools

  • Old revisions
  • Backlinks
  • Back to top
Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki