Fulltext results:
- Heating load in Passive Houses
- ld measurements: by building to the Passive House Standard, it is actually possible to achieve energy saving... to the DIN 1946 – health criterion). At 21°C and standard pressure, air has a heat capacity of 0.33 Wh/(m<s... nimal requirements. If occupants requiring a high standard of comfort are present, internal heat gains exist... e design output in accordance with the [DIN 4701] standard, even at extremely low outdoor temperatures. This
- What defines thermal bridge free design?
- the external surfaces and regular U-values of the standard building elements alone. Regularly occurring thermal bridges in standard building components must already be taken into ac... efore be decisive for achieving the Passive House standard in the first place.\\ \\ [{{:picopen:thermo_ext_
- Definition and effects of thermal bridges @basics:building_physics_-_basics:thermal_bridges
- rate and lower surface temperatures than adjacent standard building components. They occur particularly at t... oints, edges, transitions and penetrations of the standard building components. They are depicted by the lin... efore be decisive for achieving the Passive House Standard in a construction project. ==== Effect on the b
- Examples of thermal bridge calculations @basics:building_physics_-_basics:thermal_bridges:tbcalculation
- Interior walls on floor slabs @basics:building_physics_-_basics:thermal_bridges:tbcalculation:examples
- Special features and characteristics of components in contact with the ground @basics:building_physics_-_basics:thermal_bridges:tbcalculation:ground_contact
- Recommended procedure for calculating thermal bridges of components in contact with the ground @basics:building_physics_-_basics:thermal_bridges:tbcalculation:ground_contact
- Thermal comfort parameters @basics:building_physics_-_basics:thermal_comfort
- mfort equation]]). Furthermore, according to this standard it is essential that * the sultriness limit ... ing that by the requirements of the passive house standard all comfort criteria are automatically optimally
- Thermal Bridges Catalogue @basics:building_physics_-_basics:thermal_bridges
- not possible (e.g. modernisation to the EnerPHit Standard), this thermal bridge catalogue can support the d
- Adaptive versus Heat Balance Comfort Models @basics:building_physics_-_basics:thermal_comfort
- y experiments. They resulted in the international standard ISO 7730 which allows for the calculation of the
- Local thermal comfort @basics:building_physics_-_basics:thermal_comfort
- um way with the requirements of the Passive House Standard - Improved thermal insulation simultaneously impr