Fulltext results:
- Superior thermal protection is affordable @basics:affordability:investing_in_energy_efficiency
- ====== Superior thermal protection is affordable====== In **new constructions**, walls, roofs, and other e... asures offers the opportunity to adapt inadequate thermal properties of the building to future requirements. Again, thermal insulation measures can be combined with the main... rdability:Investing in energy efficiency:Superior thermal protection is affordable#Literature|[Kah, Feist 2
- Are Passive Houses cost-effective? @basics:affordability:investing_in_energy_efficiency
- ceiling it should remain 140 mm as before, with a thermal conductivity of 0.035 W/(mK).//{Remark 2015: The ... hich was very innovative at the time. Today\\ its thermal protection is still somewhat better than that req... "EnEV" house to the\\ Passive House: The superior thermal insulation.\\ Because of the improved window tech... **//|\\ \\ The existing house was also a mostly **thermal bridge free construction**; except for the increa
- Economic feasibility of Passive House design
- efficient building envelope: * more and better thermal insulation layer * windows with low U-value < ... s, see figure 3, such as: * air tightness * thermal insulation of cellar, bottom slab, outside wall, ... ergy costs can be reduced significantly by adding thermal insulation and ventilation with heat recovery, better air-tightness and less thermal bridges, etc. Several bundles of these energy sav
- Factors that influence the energy balance and affordability of non-residential EnerPHit projects @basics:affordability:investing_in_energy_efficiency:economic_feasibility_of_passive_house_retrofits
- ive House Standard for various reasons (remaining thermal bridges to the basement, suboptimal orientation, ... sive House components in order to promote optimal thermal insulation standards. Since last year's Passive H... w heating energy demand aside from the inevitable thermal bridges in old buildings. The EnerPHit standard i
- Life cycle cost analysis of energy interventions in 18 reference buildings
- oor temperature is set between 16°C and 19°C. For thermal bridges, assumptions are made that match the buil... of the facades, Insulation value of the rooftops, Thermal bridge interrupters in perimeter Window frames, G
- Investing in energy efficiency
- rdability:Investing in energy efficiency:Superior thermal protection is affordable]]\\ [[Basics:Affordabil
- Cost-effectiveness analysis @basics:affordability:investing_in_energy_efficiency
- rdability:investing_in_energy_efficiency:superior_thermal_protection_is_affordable|]]\\ [[basics:affordabil