Fulltext results:
- Sample Documents for Building Certification @certification:certified_passive_houses
- th EN ISO 10077-2 Sample {{:picopen:glazing_edge_thermal_bridge_calculation.pdf|glazing edge thermal bridge calculation}} in accordance with EN ISO 10077-2 Compl... mplates === Guidance on documenting a {{:picopen:thermal_bridges_to_ambient_air.pdf|thermal bridge calculation}} for a connection detail adjacent to ambient air
- Addendum concerning the use of vacuum insulation
- g to the relevant guidelines in EN 17140:2020-12 (Thermal insulation products for buildings - Factory-made ... itute for at least 50 years. * The rated/design thermal conductivity (lambda-R) should be established acc... nd procedures for determining declared and design thermal values) and should take into account the edges/jo... s should be easily accessible and inspectable via thermal camera to detect defects, e.g. behind a removable
- EnerPHit – the Passive House Certificate for retrofits
- ticularly effective [Bastian 2022]: * improved thermal insulation (based on the principle: if it has to ... nning:refurbishment_with_passive_house_components:thermal_envelope:minimising_thermal_bridges|reduction of thermal bridges]] {{:picopen:members_only.png?20}} * considerably [[:planning:refur
- Classic, Plus, Premium: The Passive House classes and how they can be reached @certification:passive_house_categories
- tprint, defined as the vertical projection of the thermal envelope towards ground (for details, please refe... use Plus (60 kWh/(m²ground*a)). If a small solar thermal array for hot water supply with six square meters... Friedl. }}] ==== Passive House Plus with a solar thermal array and heat recovery from shower water ==== ... parison with the original variant 1a with a solar thermal array shows that less energy is generated even th
- Certification of buildings in which the ground floor is used for commercial purposes (for PHPP 9, revised 5-Sep-2016)
- l-insulated that there won't be any impairment of thermal comfort and structural integrity, and heating cos... tifier. **Case 4 (a+b): ground floor with simple thermal protection standard because later user requiremen... l-insulated that there won't be any impairment of thermal comfort and structural integrity, and heating cos
- Certification of terraced houses and semi-detached/duplex houses according to Passive House Institute criteria
- rrace houses usually require a better standard of thermal protection on account of the larger envelope area... he requirements with a slightly lower standard of thermal protection. After completion of the certification... on and certification because the same standard of thermal protection (insulation thickness etc.) can be imp
- PER-factors for electricity use: Location & application specific decarbonisation @certification:passive_house_categories
- age potential of domestic hot water tanks (20 kWh thermal storage, η = 95 %), as well as for the thermal mass of the building (22 kWh thermal storage, η = 90 %). These additions are not scaled according to the d
- Building Certification
- building at the construction site: Airtightness, thermal bridge free design, high-quality windows and inst
- The Passive House Classes: Classic, Plus and Premium
- considered in the PER methodology (biomass, solar thermal etc.). [{{:picopen:20150311_passivehouseclasses
- Certified Passive House Components
- indow frames, highly efficient ventilation units, thermal bridge free connection details, glazing that allo
- Certification of Passive House office buildings @certification:certified_passive_houses
- he primary energy demand and will also impair the thermal comfort in summer:\\ \\ A higher occupancy level