Fulltext results:
- Energy balances - Background
- udes all areas in a building in which comfortable thermal conditions should prevail. It is usually convenie... ated areas" inside a building are included in the thermal envelope, this saves construction costs as well a... ferent rooms?**\\ We cite Ole Fanger (taken from "Thermal Comfort"): //"It is a well known fact that the in... ? Isn't the heat storage more important than the thermal insulation, and isn't the whole U-value calculati
- Dynamic simulation of a building's thermal performance
- ====== Dynamic simulation of a building's thermal performance ====== ==== Dynamic Simulation using DYNBIL ... used in instationary simulation of a buildings \\ thermal performance; this is the model-type used \\ in th... IL [Feist 1994]| \\ Dynbil is a multizone dynamic thermal building simulation program developed at the Pass... system components including the consideration of thermal comfort, ventilation, air quality, noise protecti
- PHPP – Passive House Planning Package
- (m²a)] and maximum heating load [W/m²]\\ * Summer thermal comfort with active cooling: [[.:phpp_-_the_passi... g?20}} and maximum cooling load [W/m²]\\ * Summer thermal comfort with passive cooling: frequency of overhe... s [%] (see [[:a_simplified_method_for_determining_thermal_comfort_in_summer_for_buildings_without_active_co... sioning tools for windows (with regard to optimal thermal comfort), home ventilation (with regard to optima
- PHPP - validated and proven in practice @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- locations. \\ This project demonstrated that the thermal characteristics of buildings - even in the case o... nstitut, Darmstadt 1997 \\ //Energy balances and thermal characteristics; Protocol Volume No. 5 of the Res... mulationsprogramm DYNBIL: Dynamische Simulation) Thermal building simulation, first edition,1994 (link to
- Internal heat gains in relation to living area @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- se is released into the outdoor air. * A solar thermal system is not considered * The electricity con... sehold appliances present and are they within the thermal envelope? Is the presence of occupants similar to
- Calculation guide for temperature reduction factors to temperature zone "X" in the PHPP "Areas" worksheet @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- se it may already make sense to include it in the thermal envelope. If not, a reduction factor of e.g. 6/7
- “designPH” plugin for Trimble Sketchup @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- ocess ===== The model geometry is marked-up with thermal properties, with the aid of some automatic analys