Fulltext results:
- Airtightness and airtightness measurement @planning:refurbishment_with_passive_house_components:thermal_envelope
- in Frankfurt a.M., Ludwigshafen and Nuremberg. In these complete refurbishments, values between 0.4 and 0... ess may be inadequate can be checked or detected. These findings should then be incorporated into the pla... stove) may not be closed or sealed for the test. These openings are essential during operation and alway... If there are staircases inside the airtight layer these are also added with their base area and clear hei
- Step-by-step Retrofits towards EnerPHit Standard in social housing in Spain
- the social housing refurbishment issues. Most of these social houses are not rented but owned. The fact ... or replace components at a certain point in time. These changes coexist with original components or with ... t require making a decision on the fly. Moreover, these retrofits are performed by small companies where ... ol is done at the end of the works, not even when these works are financed or subsidised with public mone
- Building Integrated Photovoltaics (BIPV) in Step by Step Retrofitting Projects
- urtain walls, roofs, balcony railings and floors. These multifunctional bioclimatic solutions combine bot... des and glazing surfaces. This paper will present these solutions focusing on their applications in warm ... e best result in terms of kWh/kWp installed under these irradiation conditions. The a-Si technology impro... y the photovoltaic glass, values go from 7 to 9%. These values are similar to conventional glazing which
- Component Award 2016: Affordable ventilation solutions for retrofits
- istribute the supply air into neighbouring rooms. These ventilators have very low power consumption of ab... ctional rooms. If the device itself does not meet these requirements, additional steps must be taken and ... nts and maintenance. An independent jury assessed these factors. ===== 5. Outlook ===== At the time thi
- Improving thermal bridges and airtightness in existing buildings @planning:refurbishment_with_passive_house_components:thermal_envelope
- g walls penetrating through the basement ceiling. These details will be discussed in the present article ... ecting balcony slabs etc). During the planning of these details the principles of thermal bridge free des... a number of the details in old buildings. One of these is to position the airtight envelope at the level
- Overall retrofit plan for step-by-step retrofits to EnerPHit Standard
- ARIANTS’) of exactly the same type and allocating these to the windows that will be modernised in the cor... you will be able to assign component qualities to these elements which will be improved in different retr
- Prospects for the modernisation of existing buildings using highly efficient components
- modernisation of existing buildings. Originally, these components were developed for use in new construc... ation is both practicable and cost-effective. \\ These measures \\ • offer greater security against mois
- Step-by-step deep retrofit and building integrated façade/roof on a 'million program' house
- ditional homes in Sweden [1, 2]. Needless to say, these buildings are in great need of renovation today, ... sulated with 500 mm cellulose fibre (cold attic). These upgrades have already reduced the heating demand
- Windows in a step-by-step retrofit
- in the new insulation later are a good option. In these cases, the frame and the front-mounted box should... sation does not build up as so often happens with these old windows, thereby preventing the frame from ro
- Influence of retrofitting on daylighting @planning:refurbishment_with_passive_house_components:mechanical_systems
- utomated assessment loop was developed to examine these light issues, combining the Matlab math software ... n are also quoted. \\ \\ ===== Read more ===== //These in-depth articles are available exclusively to iP
- Insulation measures for the external envelope @planning:refurbishment_with_passive_house_components:thermal_envelope
- 24]. Depending on the type of building component, these figures may be even more extreme. In the case of ... nsulation of the exterior wall. Solutions to both these problems will be presented in the following secti
- Refurbishment with Passive House components - introduction
- alternative is more “worthwhile“? The result of these analyses of the respective burden over the period
- Crosstalk silencers @planning:refurbishment_with_passive_house_components:ventilation
- cted by means of **crosstalk sound attenuators**. These can consist, for example, of a duct section with