• skip to content

User Tools

  • Log In

Site Tools

  • Recent Changes
  • Media Manager
  • Sitemap
You are here: Cloud Plugin » use

use

Search

You can find the results of your search below.

Exact match
  • Exact match
  • Starts with
  • Ends with
  • Contains
@planning:calculating_energy_efficiency
  • Any namespace
  • planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package (3)
Any time
  • Any time
  • Past week
  • Past month
  • Past year
Sort by hits
  • Sort by hits
  • Sort by last modified

Matching pagenames:

  • PHPP – Passive House Planning Package
  • Calculation guide for temperature reduction factors to temperature zone "X" in the PHPP "Areas" worksheet
  • PHPP calculations in hot and humid climates
  • “designPH” plugin for Trimble Sketchup
  • Internal heat gains in relation to living area
  • PHPP - validated and proven in practice
  • The overall heat transfer coefficient or U-value
  • Variant calculations and economic assessment with PHPP 9

Fulltext results:

Internal heat gains in relation to living area @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
7 Hits, Last modified: 3 years ago
unately. Below, as well as in the PHPP 9, we will use the data from Germany. [{{picopen:average_occupan... ilability of the dissipated heat depending on the use must be taken into account. If this is done and t... I points out that it is not permissible at all to use such high values for the planning of Passive Hous... which the standard values for IHG for residential use will result. However, the high values calculated
Dynamic simulation of a building's thermal performance
4 Hits, Last modified: 5 years ago
* The assessment of components for solar energy use (such as transparent heat insulation) with regard... omponents from the (coarser) overall model and to use them for detailed individual models of components... el of the mathematical model: in this respect the use of computer simulation does not mean a principien... oor climate and heating energy consumption is the use of thermal computer aided building models. - On t
Energy balances - Background
4 Hits, Last modified: 5 years ago
Why are specific values necessary? ==== If the use of absolute consumption divided by reference area... lute consumption values therefore are not of much use. What must be considered is the **consumption (e... (e.g. the German Engineers Association) prefer to use the **gross volume V** as a reference value (kWh/... eration_and_experience:measurement_results:energy_use_measurement_results|measurement results]]. The t
PHPP - validated and proven in practice @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
2 Hits, Last modified: 12 months ago
eration_and_experience:measurement_results:energy_use_measurement_results#summary|fluctuation of the en... d result in unrealistically low values for energy use, suggesting that very low or even zero-energy hou
Variant calculations and economic assessment with PHPP 9 @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
2 Hits, Last modified: 6 years ago
as a long track record as an accurate and easy-to-use tool for planning Passive House buildings and Ene... t partners are gradually testing this version for use in a gradual modernization project as part of the

Page Tools

  • Old revisions
  • Backlinks
  • Back to top
Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki
    DE EN