Fulltext results:
- The world’s first Passive House, Darmstadt-Kranichstein, Germany @examples:residential_buildings:multi-family_buildings:central_europe
- ch houses can be kept warm "passively", solely by using the existing internal heat sources and the solar ... educe the heating energy requirement to "zero" by using inefficient electrical devices, for example, whic... andardisation, calculations are still carried out using values that are far too optimistic((This is one o... re|[Feist 1997c] ]]. * The hot water is heated using solar vacuum flat collectors (5.3 m² per househol
- Playing in a Passive House - A timber/mudbrick building for children @examples:non-residential_buildings:passive_house_kindergartens:central_europe
- vades the rooms thanks to the construction method using safe building materials and to the controlled ven... pg?300 }}| |//**Bricking in of the interior walls using mudbricks.**//|\\ \\ The gallery and auxiliary ro... übingen, a concept for improving the air humidity using indoor plants was developed, as these are ideal h... rmore, the outdoor air quality can be improved by using fine filters (to prevent pollen being carried in)
- Playing on the Passive House hill - the new kindergarten in the Heidenau city park @examples:non-residential_buildings:passive_house_kindergartens:central_europe
- lue 0. 11 W/(m²K)). The external walls are built using highly insulating bricks filled with perlite comp... constant air flow in the staff rooms is achieved using a volumetric flow regulator. The supply air flow
- The Nestwerk Residential Project in Dresden @examples:residential_buildings:multi-family_buildings:central_europe
- ve Houses with a total of 9 apartments were built using ecological building materials and technologies. T... or the inside and the outside. Joints were sealed using cotton wool and flax fibre. In some areas, clay b
- Riedberg Passive House School, Frankfurt, Germany @examples:non-residential_buildings:passive_house_schools
- 1500 ppm**. The actual air changes were measured using a tracer gas test. The designed value ranging bet
- Riedberg Passive House School, Frankfurt, Germany @examples:non-residential_buildings:passive_house_schools:central_europe
- 1500 ppm**. The actual air changes were measured using a tracer gas test. The designed value ranging bet
- Multi-family Passive House buildings in Germany @examples:residential_buildings:multi-family_buildings:central_europe
- ll**, \\ provided that they are carefully planned using the PHPP.\\ The research report has been publishe
- “Am Buir”, Wassenberg, Germany – the world’s smallest Passive House @examples:residential_buildings:single_-_family_houses:central_europe
- The first layer of insulation panels was applied using adhesive and dowels. Three vertical lines of adhe