Fulltext results:
- Internal heat gains in relation to living area @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- he PHPP 9 (2015). The calculations were performed using the PHPP 8; however, some additions have been mad... cial for practical planning. An additional review using other approaches (e.g. for specific known occupan... ng heat gains will arise per person: * Lighting using 100% energy saving lamps (fluorescent lamps as we... ributions have been summarised in Figure 7, again using the example of a dwelling unit with a living area
- Dynamic simulation of a building's thermal performance
- ermal performance ====== ==== Dynamic Simulation using DYNBIL ==== |{{:picopen:network_eng_s.png|}}| |F... can be tackled numerically with some effort today using the Navier-Stokes equations, a solution to the ov... ility of the simulation models. The advantage of using adequate mathematical models (and the resulting p... ion to a "standard climate" would have to be done using the theoretical models that we wanted to avoid by
- Energy balances - Background
- s enter the building through the same\\ envelope. Using the law of energy conservation,\\ the sum of the ... maining heat supply required (the heating demand) using the energy balance.\\ \\ * There's just a litt... th a little effort, this problem can be solved by using **simulation programmes** (see [[Planning:calcula... **//||\\ \\ The balance shown here was calculated using the PHPP; it belongs to the Passive Houses built
- PHPP - validated and proven in practice @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- red objects were compared with calculated results using the [[planning:calculating_energy_efficiency:phpp... ould be reproduced with a high degree of accuracy using the energy balancing software programme PHPP. Thi... AE140_Summary.pdf|SumamaryValidation of PHPP v9.6 using ANSI/ASHRAE Standard 140-2017]]** \\ In January 2... tion-report-jan-23-2019.pdf |PHPP V9.6 Validation using ANSI/ASHRAE Standard 140-2017}} [[planning:calc
- PHPP – Passive House Planning Package
- tion-report-jan-23-2019.pdf |PHPP V9.6 Validation using ANSI/ASHRAE Standard 140-2017}} {{ :picopen:euro
- Calculation guide for temperature reduction factors to temperature zone "X" in the PHPP "Areas" worksheet @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- frost-free, a reduction factor can be calculated using the MS Excel tool provided by PHI. The tool uses
- “designPH” plugin for Trimble Sketchup @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- d energy balance calculations can be interrogated using the web-dialog windows provided. These also allow