Fulltext results:
- PB 41: Planning tools for the summer situation in non-residential buildings @phi_publications:pb_41
- ial and non-residential buildings correspond very well with the dynamic simulation. In the energy bala... also proved successful for inhabited buildings as well as in the direct probation of inhabited buildings... The calculation was carried out using the PHPP as well as the dynamic model in DYNBIL as the comparison ... igure 4). Both calculation methods correlate very well if there are no windows areas or if window areas
- Passive House and the Sustainable Development Goals (SDGs): Connecting an international building standard with global aims @basics
- d into eight umbrella categories: * Health and well-being: Contributing to health and well-being by providing a cost-efficient, resilient, and healthy envi... energy prices and bloated fossil fuel demand, as well as mould and moisture damage. * Sustainable co... lthy and comfortable homes for the vulnerable, as well as in climate resilience. The extremely low heati
- Energy Efficiency in Domestic Electrical Energy Use @sinfonia
- better appliances with only long-term rewards as well as the shortage in capital that prevents low-inco... s evaluated for total energy use per apartment as well as per sector of application. Based on the annual... water)-preparation based on electricity or not as well as for the number of persons and the fact whether... ery small households with high electricity use as well as for 4-person households. Given the not represe
- Insulation vs. thermal mass @planning:thermal_protection:thermal_protection_works
- ulated hot water bottle (one which is not under a well-insulating duvet) releases its heat content withi... s to be constantly supplied by the hot-plate.\\ A well-insulated storage container (**left, thermos\\ fl... the calculations made using it correspond just as well with building physical measurements as shown in [... sions. The values thus calculated correspond very well with measurements. The same is true for processes
- The world’s first Passive House, Darmstadt-Kranichstein, Germany @examples:residential_buildings:multi-family_buildings:central_europe
- the solar energy entering through the windows as well as by a minimal heating of incoming fresh air((We... e been placed inside the thermal envelope and are well insulated.\\ \\ ==== Ventilation ==== === Heat ... iterature|[Rohrmann 1994]]]. Due to particularly well-insulating and airtight sliding shutters as tempo... as a generally used solution - but recommends the well-approved Passive House standard.)) \\ \\ |{{ :pic
- Heating load in Passive Houses @basics:building_physics_-_basics
- s a crucial difference, especially in the case of well-insulated buildings. * Buildings with very sma... === Problems calculating the heating load in very well-insulated buildings ===== \\ It was shown that the heat output in very well-insulated buildings, actually measured through sc... ng into account solar gains, particularly in very well-insulated buildings. \\ It was thus necessary to
- Energy balances - Background @planning:calculating_energy_efficiency
- the insulation), and the internal heat sources as well as the passively utilised solar energy can be estimated well enough, it is possible to calculate the remaining... hort time intervals. Fortunately, there are some well-validated **simplified formulas** available for t... n, it does describe the function of heating quite well, especially for a high quality building envelope.
- The Passive House in summer @basics
- ample is that of keeping chilled water cool in a (well-insulating) thermos flask.)) In this study we doc... d temperature course of surface and indoor air as well as the operative temperature\\ during the critica... ons: the g-values of both are almost identical as well. //This analysis shows that in residential build... heating demand (between 10 and 12 kWh/(m²yr)) as well as the frequency of summertime overheating events
- Thermal insulation @planning:thermal_protection
- demand the entire **building envelope** has to be well insulated. The building envelope consists of all ... whole building so as to eliminate cold corners as well as excessive heat losses. This method is another ... es with existing Passive Houses working perfectly well based on these calculations. In terms of heating,... Such low U-values can only be achieved with very well-insulating materials. The following table shows
- Energy efficiency of the Passive House Standard: Expectations confirmed by measurements in practice @operation:operation_and_experience:measurement_results
- onsumption of 13.4 kWh/(m²a) correlates extremely well with the previously calculated demand of 13 kWh/(... . In this project too, the measured result agrees well with the previously calculated (PHPP) demand valu... bruck, AEE-INTEC, IFZ), the energy consumption as well as user satisfaction and indoor air quality in th... bility of the PHPP as an energy balancing tool as well as a planning tool for highly energy efficient re
- Insulation works – Evidence no.1 "Measurements at a highly insulated wall" @planning:thermal_protection:thermal_protection_works
- built into the surfaces and the structure of very well insulated walls. The cross-sectional view of the ... ntire period of time outdoor air temperatures are well below the room temperature: Outdoor temperatures ... provides further evidence: Insulation works very well; very little heat flows through the insulation la... 0.1 degrees or less. This view confirms just how well the calculated values (clack curves) match the me
- Certification of buildings in which the ground floor is used for commercial purposes (for PHPP 9, revised 5-Sep-2016) @certification
- boundary and is assumed as adiabatic. In the stairwell area etc. the boundary can also be at the ceiling... t have to continue down to the ground in the stairwell area). c) In addition, a separate PHPP calculati... the ground floor and the first floor should be so well-insulated that there won't be any impairment of t... of the airtight layer and the insulation layer as well as the connection of these layers to the storey a
- Planning criteria for Passive Houses in New Zealand @basics:passive_houses_in_different_climates
- ssion losses and optimised use of solar gains, as well as with minimised ventilation heat losses by mean... culated both with the dynamic simulation tool, as well as the PHPP, in order to test the reliability of ... presented in this report show, however, that in a well-planned and well-built Passive House there will be no condensation and no mould. The basic prerequisite
- Philips Experimental House Research 1974ff: Passive versus Active Measures in Europe & America @basics:the_passive_house_-_historical_review
- red by Scandinavian work on low energy houses, as well as American efforts on passive solar buildings a... n, model-experiment and inter-model validation as well as system and component simulation under a wide v... Note, these conclusions included old buildings as well, where considerable saving potentials were seen a... e South façade do not lead to additional gains in well-insulated houses – which is consistent with later
- Thermal comfort parameters @basics:building_physics_-_basics:thermal_comfort
- y depends on the "thermal comfort". This has been well-researched and the results have been incorporated... ivity (e.g. sleeping, running...) and clothing as well as the determining factors for the thermal surrou... and the room air) and the interior surface of the well insulated building component. \\ The practi... ublication [ 1 ]. The comfort characteristics of well insulated buildings can be observed in practice a
- Passive House – the next decade | Determining application-specific PER factors @basics:passive_house_-_assuring_a_sustainable_energy_supply:passive_house_the_next_decade
- PHPP - validated and proven in practice @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- Introduction - Passive House buildings in different climates @basics:passive_houses_in_different_climates
- PER-factors for electricity use: Location & application specific decarbonisation @certification:passive_house_categories
- Economy and financing of efficiency: new buildings, renovation and step by step retrofit @basics:affordability:investing_in_energy_efficiency
- Energy use for heating in a well insulated new building @planning:thermal_protection:thermal_protection_works
- The promotion of low energy construction and the Passive House Standard: Successful strategies for forming a Passive House Association @experiences:connecting_the_passive_house_community
- Building Integrated Photovoltaics (BIPV) in Step by Step Retrofitting Projects @planning:refurbishment_with_passive_house_components
- Refurbishment with Passive House components - introduction @planning:refurbishment_with_passive_house_components
- Internal heat gains in relation to living area @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- Playing in a Passive House - A timber/mudbrick building for children @examples:non-residential_buildings:passive_house_kindergartens:central_europe
- Evaluation of server and server room efficiency for non-residential buildings that exceed the primary energy criterion @certification
- Life Cycle energy balances, Embodied energy and the Passive House Standard @basics:energy_and_ecology
- Checklist: Test reports of airtightness measurements @planning:airtight_construction:general_principles
- Comparison of energy performance of ventilation systems using passive vs. active heat recovery @planning:building_services:ventilation
- Passive House - 6 reasons why you still need opening windows @planning:building_services:ventilation
- Baseline study - implementing the Passive House concept in hospitals @planning:non-residential_passive_house_buildings:ph_hospitals
- Airtightness and airtightness measurement @planning:refurbishment_with_passive_house_components:thermal_envelope
- Neuwerk Caritas-Haus, Germany - the world’s first Passive House nursing home for the elderly @examples:residential_buildings:nursing_homes:central_europe
- Comparison of in-situ measurements and hygrothermal simulations of four different interior insulation systems @planning:thermal_protection:thermal_protection_works:comparison_of_in_situ_measurements_and_hygrothermal_simulations_of_four_different_interior_insulation_systems
- Exterior wall on floor slab @basics:building_physics_-_basics:thermal_bridges:tbcalculation:examples
- Electric Energy Efficiency for Households – Doing the whole step towards energy efficiency @sinfonia
- Efficiency of household appliances and their impact on the primary energy demand of residential buildings @basics:passive_house_-_assuring_a_sustainable_energy_supply
- Classic, Plus, Premium: The Passive House classes and how they can be reached @certification:passive_house_categories
- Erfurt University of Applied Sciences – Faculty of Architecture @education_training:university_programmes
- Component Award 2016: Affordable ventilation solutions for retrofits @planning:refurbishment_with_passive_house_components
- Overall retrofit plan for step-by-step retrofits to EnerPHit Standard @planning:refurbishment_with_passive_house_components
- Prospects for the modernisation of existing buildings using highly efficient components @planning:refurbishment_with_passive_house_components
- Step-by-step deep retrofit and building integrated façade/roof on a 'million program' house @planning:refurbishment_with_passive_house_components
- Step-by-step Retrofits towards EnerPHit Standard in social housing in Spain @planning:refurbishment_with_passive_house_components
- Passive House – the next decade | Methodology @basics:passive_house_-_assuring_a_sustainable_energy_supply:passive_house_the_next_decade
- Riedberg Passive House School, Frankfurt, Germany @examples:non-residential_buildings:passive_house_schools
- Variant calculations and economic assessment with PHPP 9 @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
- Passive House schools – How to go about it @planning:non-residential_passive_house_buildings:passive_house_schools
- Passive House Schools - Boundary Conditions @planning:non-residential_passive_house_buildings:passive_house_schools
- Multi-family Passive House buildings in Germany @examples:residential_buildings:multi-family_buildings:central_europe
- St. Josef Caritas-Haus, Germany - the first prefabricated large module Passive House nursing home @examples:residential_buildings:nursing_homes:central_europe
- PHI window certification: previous success and new climate zones @planning:thermal_protection:windows:window_certification