• skip to content

User Tools

  • Log In

Site Tools

  • Recent Changes
  • Media Manager
  • Sitemap
You are here: Cloud Plugin » well

well

Search

You can find the results of your search below.

Exact match
  • Exact match
  • Starts with
  • Ends with
  • Contains
@planning
  • Any namespace
  • planning:thermal_protection (10)
  • planning:refurbishment_with_passive_house_components (9)
  • planning:building_services (7)
  • planning:calculating_energy_efficiency (6)
  • planning:non-residential_passive_house_buildings (5)
  • planning:airtight_construction (3)
  • planning:planning (1)
Any time
  • Any time
  • Past week
  • Past month
  • Past year
Sort by hits
  • Sort by hits
  • Sort by last modified

Matching pagenames:

  • Energy use for heating in a well insulated new building

Fulltext results:

Insulation vs. thermal mass @planning:thermal_protection:thermal_protection_works
10 Hits, Last modified: 3 years ago
ulated hot water bottle (one which is not under a well-insulating duvet) releases its heat content withi... s to be constantly supplied by the hot-plate.\\ A well-insulated storage container (**left, thermos\\ fl... the calculations made using it correspond just as well with building physical measurements as shown in [... sions. The values thus calculated correspond very well with measurements. The same is true for processes
Energy balances - Background @planning:calculating_energy_efficiency
8 Hits, Last modified: 5 years ago
the insulation), and the internal heat sources as well as the passively utilised solar energy can be estimated well enough, it is possible to calculate the remaining... hort time intervals. Fortunately, there are some well-validated **simplified formulas** available for t... n, it does describe the function of heating quite well, especially for a high quality building envelope.
Thermal insulation @planning:thermal_protection
6 Hits, Last modified: 4 years ago
demand the entire **building envelope** has to be well insulated. The building envelope consists of all ... whole building so as to eliminate cold corners as well as excessive heat losses. This method is another ... es with existing Passive Houses working perfectly well based on these calculations. In terms of heating,... Such low U-values can only be achieved with very well-insulating materials. The following table shows
Insulation works – Evidence no.1 "Measurements at a highly insulated wall" @planning:thermal_protection:thermal_protection_works
6 Hits, Last modified: 3 years ago
built into the surfaces and the structure of very well insulated walls. The cross-sectional view of the ... ntire period of time outdoor air temperatures are well below the room temperature: Outdoor temperatures ... provides further evidence: Insulation works very well; very little heat flows through the insulation la... 0.1 degrees or less. This view confirms just how well the calculated values (clack curves) match the me
PHPP - validated and proven in practice @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
5 Hits, Last modified: 12 months ago
e results of the average measured values agree so well with the PHPP calculation. This is probably coinc... re correction factors** are often set too low for well-insulated buildings: e.g. for top floor ceilings,... algorithms were developed with highly efficient, well-insulated buildings in mind, the PHPP can be used... software results. The results of PHPP agreed very well with those of the reference software. For heating
Outdoor thermography @planning:thermal_protection:thermal_protection_works
5 Hits, Last modified: 3 years ago
the filling on the old plaster (light\\ grey) as well as the insulation panels (dark grey) which have\\... on the radiation intensity of the materials\\ as well as their emissivity. This value varies very littl... 20 degrees Celsius revealing the tilted window as well as the window sill (light purple). The temperatur... lose to 19°C. This example illustrates just how well the insulation works: Even with the window open,
Types of ventilation @planning:building_services:ventilation:basics
5 Hits, Last modified: 2 years ago
d" by thermal protection at all, on the contrary, well insulated external walls have warmer and therefor... === How often should the windows be opened? ==== Well, the answer to this is difficult: the general con... air systems, the kitchen, bathroom and toilet as well as other areas with high humidity and odours are ... gh in comparison with all other heat flows in the well insulated Passive House.\\ \\ This highly efficie
Energy use for heating in a well insulated new building @planning:thermal_protection:thermal_protection_works
4 Hits, Last modified: 6 years ago
====== Energy use for heating in a well insulated new building ====== Here is further evidence that ins... ===== First of all Passive Houses are extremely well insulated including extra thick layers of insulation on all exterior walls and the roof as well as super-insulated windows. The ventilation syste... alues recorded in these Passive Houses agree very well with the generally accepted calculation methods u
Compact HVAC systems @planning:building_services
3 Hits, Last modified: 5 years ago
asics:Types of ventilation|home ventilation]], as well as the article comparing the efficiency of [[plan... stems' are the best choice that allow heating, as well as cooling and dehumidification with one integrat... more sophisticted controller and all parts to be well combined. The basic technology components are alr
Dynamic simulation of a building's thermal performance @planning:calculating_energy_efficiency
3 Hits, Last modified: 5 years ago
uilding model with air flows between the zones as well as components connecting the different zones.| D... n possible to predict the energy consumptions, as well as to test several variations of the model itself... ratures at the surface and inside the west facing well.| ==== General Considerations on Models used fo
Building Integrated Photovoltaics (BIPV) in Step by Step Retrofitting Projects @planning:refurbishment_with_passive_house_components
3 Hits, Last modified: 6 years ago
d the world. It has been proved to work extremely well in Mediterranean climates and not only in residen... y allows a certain degree of semi-transparency as well as the large variety in form, structure, and colo... accurately the heat fluxes through the walls, as well as the evolution of associated surface temperatur
Refurbishment with Passive House components - introduction @planning:refurbishment_with_passive_house_components
3 Hits, Last modified: 6 years ago
with outside connections. Constructions that are well-insulated on the outside remain free from condens... rfaces, thermal comfort in winter is increased. A well-balanced radiant climate is created, even without... l, crafts businesses, architects and engineers as well as manufacturers are called upon to take action f
Windows in a step-by-step retrofit @planning:refurbishment_with_passive_house_components
3 Hits, Last modified: 9 years ago
h a permanently elastic sealing agent (Figure 1). Well insulated Passive House frames are required for t... with the exterior masonry; then, it can be easily well insulated at a later time. Windowsills need to be... re working on solutions for stationary glazing as well. ===== 3. First insulation, then windows =====
Don’t save on the insulation @planning:thermal_protection
3 Hits, Last modified: 5 years ago
applying insulation at the same time – it will be well worth it! * Don't save on the insulation thick... ached again. So, the price here was guessed quite well. In future it might be somewhat higher due to the... the future. This benefits the whole community as well as the individual.\\ \\ ===== Conclusion ===== D
Thermal protection works @planning:thermal_protection
3 Hits, Last modified: 6 years ago
experience with highly insulated new buildings as well as older buildings retrofitted with heat insulati... ion_works_-_evidence_no.2_heating_energy_use_in_a_well_insulated_new_building|Evidence no.2]] - ** Insulation saves energy** - Heating energy use in a well insulated new building \\ \\ [[planning:thermal_p
Internal heat gains in relation to living area @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
3 Hits, Last modified: 3 years ago
Passive House swimming pools @planning:non-residential_passive_house_buildings:swimming_pools
3 Hits, Last modified: 13 months ago
Non-residential Passive House buildings
2 Hits, Last modified: 14 months ago
Tools
2 Hits, Last modified: 10 months ago
PHPP – Passive House Planning Package @planning:calculating_energy_efficiency
2 Hits, Last modified: 12 months ago
Thermal protection and modernisation of existing buildings @planning:planning
2 Hits, Last modified: 6 years ago
Checklist: Test reports of airtightness measurements @planning:airtight_construction:general_principles
2 Hits, Last modified: 23 months ago
Why build an airtight house? – Leakage problems @planning:airtight_construction:general_principles
2 Hits, Last modified: 6 years ago
Comparison of energy performance of ventilation systems using passive vs. active heat recovery @planning:building_services:ventilation
2 Hits, Last modified: 2 years ago
Passive House - 6 reasons why you still need opening windows @planning:building_services:ventilation
2 Hits, Last modified: 6 years ago
Baseline study - implementing the Passive House concept in hospitals @planning:non-residential_passive_house_buildings:ph_hospitals
2 Hits, Last modified: 2 years ago
Airtightness and airtightness measurement @planning:refurbishment_with_passive_house_components:thermal_envelope
2 Hits, Last modified: 10 months ago
Comparison of in-situ measurements and hygrothermal simulations of four different interior insulation systems @planning:thermal_protection:thermal_protection_works:comparison_of_in_situ_measurements_and_hygrothermal_simulations_of_four_different_interior_insulation_systems
2 Hits, Last modified: 6 years ago
Calculating energy efficiency
1 Hits, Last modified: 5 years ago
Heat pump tool
1 Hits, Last modified: 14 months ago
PHErde
1 Hits, Last modified: 3 years ago
Airtightness measurements in Passive Houses @planning:airtight_construction
1 Hits, Last modified: 2 years ago
Heating and DHW @planning:building_services
1 Hits, Last modified: 7 years ago
Introduction: Retail stores as Passive Houses @planning:non-residential_passive_house_buildings
1 Hits, Last modified: 7 years ago
Component Award 2016: Affordable ventilation solutions for retrofits @planning:refurbishment_with_passive_house_components
1 Hits, Last modified: 6 years ago
Overall retrofit plan for step-by-step retrofits to EnerPHit Standard @planning:refurbishment_with_passive_house_components
1 Hits, Last modified: 6 years ago
Prospects for the modernisation of existing buildings using highly efficient components @planning:refurbishment_with_passive_house_components
1 Hits, Last modified: 7 years ago
Step-by-step deep retrofit and building integrated façade/roof on a 'million program' house @planning:refurbishment_with_passive_house_components
1 Hits, Last modified: 5 years ago
Step-by-step Retrofits towards EnerPHit Standard in social housing in Spain @planning:refurbishment_with_passive_house_components
1 Hits, Last modified: 9 years ago
Variant calculations and economic assessment with PHPP 9 @planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package
1 Hits, Last modified: 6 years ago
Passive House schools – How to go about it @planning:non-residential_passive_house_buildings:passive_house_schools
1 Hits, Last modified: 8 years ago
Passive House Schools - Boundary Conditions @planning:non-residential_passive_house_buildings:passive_house_schools
1 Hits, Last modified: 4 years ago
Types of glazing and their specific values @planning:thermal_protection:windows
1 Hits, Last modified: 3 years ago
Air volumes @planning:building_services:ventilation:basics
1 Hits, Last modified: 6 years ago
PHI window certification: previous success and new climate zones @planning:thermal_protection:windows:window_certification
1 Hits, Last modified: 3 years ago
Sound generation, sound dispersion and sound proofing in heat pumps @planning:building_services:heating_and_dhw:heating:heat_pumps
1 Hits, Last modified: 7 years ago

Page Tools

  • Old revisions
  • Backlinks
  • Back to top
Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki
    DE EN